Heart Rate Chest Strap Battery Replacement; Troubleshooting - Nautilus R618 Service Manual

Recumbent bike
Hide thumbs Also See for R618:
Table of Contents

Advertisement

Heart Rate Chest Strap Battery Replacement

The heart rate (HR) chest strap uses a CR2032 battery.
1.
Using a coin, loosen the slotted cover on the battery bay. Remove the cover
and battery.
2.
When replacing the battery, insert it in the battery bay with the + symbol
facing up.
3.
Reinstall the cover on the strap.
4.
Discard the old battery. Dispose of in accordance with local regulations and/
or at approved recycling centers.
5.
Inspect your chest strap to ensure function.
Do not use until the equipment has been fully assembled and inspected for correct performance in

Troubleshooting

Condition/Problem
No display/partial display/
unit will not turn on
Unit operates but Contact
HR not displayed
Things to Check
Check electrical (wall)
outlet
Check connection at front
of unit
Check data cable integrity
Check data cable
connections/orientation
Check console display for
damage
Console Display
HR cable connection at
Console
Sensor grip
Dry or calloused hands
Static Handlebar
Make sure unit is plugged into a functioning wall outlet.
Connection should be secure and undamaged. Replace
adapter or connection at unit if either are damaged.
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check for visual sign that console display is cracked or other-
wise damaged. Replace Console if damaged.
replace the Console.
If the above steps do not resolve the problem, contact Cus-
tomer Service (if inside US/Canada) or your local distributor (if
outside US/Canada).
Be sure cable is connected securely to Console.
Be sure cables from handlebars and cable to Console are
secure and undamaged.
Be sure hands are centered on HR sensors. Hands must be
kept still with relatively equal pressure applied to each side.
A conductive electrode cream (heart rate cream) can help
make better conduct. These are available on the web or at
If tests reveal no other issues, Static Handlebar should be
replaced.
7
CR2032
+
Solution