5.7 Hydraulic connection

Before connecting the hydraulic system, make sure
the appliance has been disconnected from the
electrical mains.
5.7.1
Water supply
The appliance's water supply must provide water which is
suitable for human consumption, and must conform with the
regulations in force in the place of installation. The owner/
manager of the system must provide the Technician with con-
firmation that the water meets the above requirements.
Materials to be used
5.7.2
When installing the appliance, only the components and ma-
terials supplied with the appliance are to be used. Should the
use of other components be necessary, the Technician must
verify that these are suitable for coming into contact with wa-
ter used for human consumption.
Hydraulic connections
5.7.3
The Technician must carry out the hydraulic connections in
accordance with the hygiene and hydraulic safety standards
regarding environmental protection which are in force in the
place of installation.
• Add a valve to the water supply in order to stop water
flowing to the machine.
• In order to prevent damage, it is advisable to install the
water purification filter where it will be protected from ac-
cidental blows.
• If there is no water purification filter (9), connect the wa-
ter mains (15) directly to the machine's water inlet (6).
• When connecting the machine's tray (5) to the sewer
drain (4), avoid overly tight curves or kinks, and make sure
that there is sufficient inclination for water to flow to the
drain.
• The drain must be connected to a siphon that can be in-
spected and periodically cleaned, in order to prevent un-
pleasant odours returning.
• To avoid oxidisation building up and damage to the ma-
chine over time, do not use iron connections for the hy-
draulic system, even if they are galvanised.
TECHNICIANS' manual
11
After installation and before using the machine,
the water in the hydraulic circuits must be re-
placed, as indicated in para. 6.7.
New connecting pipes must be used every time
that the machine is newly installed. Do not use old
connecting pipes.
The water mains must supply cold water fit for hu-
man consumption (potable water) at a pressure
between 0.15-0.6 Mpa (1.5 and 6 bar). If the pres-
sure is higher than 0.6 MPa (6 bar), connect a pressure re-
ducer before the pump.
All the filling couplings are 3/8 male gas types. The drain
tray is connected to a pipe with an internal diameter of 20
mm.
If an external tank is used, the connection pipe between the
machine and the tank must not exceed 150 cm.
The machines are fitted with a "Timeout" device which al-
lows the heating unit to be filled up with water within a
maximum time. This function prevents water from flowing
out of the heating unit's valve (flooding) and keeps the mo-
tor pump from overheating.