Refrigerant Circuit

The refrigerant circuit is difficult to check for leaks without the proper
equipment. If inadequate cooling is suspected, contact your local dealer
for service.
WARNING
!
EXPLOSION, BURN AND ENVIRONMENTAL HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
System under pressure. Relieve pressure and recover all refrigerant
before system repair or final unit disposal. Use all service ports and
open all flow-control devices, including solenoid valves.
Unit Panels
After performing any maintenance or service on the unit, be sure all
panels are fastened securely in place to prevent rain from entering unit
cabinet and to prevent disruption of the correct unit airflow pattern.
Regular Dealer Maintenance (Refer to
In addition to the type of routine maintenance you might be willing to
perform, your unit should be inspected regularly by a properly trained
service technician. An inspection (preferably each year) should include
the following:
1. Inspection and, if required, cleaning of the outdoor and indoor
coils.
2. Inspection and, if required, cleaning of the indoor coil drain pan.
3. Inspection and cleaning of blower wheel housing and motor.
4. Inspection of all supply and return air ducts for leaks, obstructions,
and insulation integrity. Any problems found should be resolved at
this time.
5. Inspection of the unit base to ensure that no cracks, gaps, etc., exist
which may cause a hazardous condition.
6. Inspection of the unit casing for signs of deterioration.
7. Inspection of all electrical wiring and components to assure proper
connection.
8. Inspection for leaks in the refrigerant circuit. Pressure
temperature check to determine appropriate refrigerant charge.
9. Operational check of the unit to determine working conditions.
Repair or adjustment should be made at this time.
Your servicing dealer may offer an economical service contract that
covers seasonal inspections. Ask for further details.
Complete service instructions can be found in the unit Installation,
Start-up and Service Instructions.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Warranty Certificate

Your unit has a limited warranty. Be sure to read the warranty carefully
to determine the coverage for your unit.
Before you call for service...
...check for several easily solved problems.
If insufficient heating or cooling is suspected:
( ) Check for sufficient airflow. Check the air filter for dirt. Check for
blocked return or supply air grilles. Be sure they are open and
unobstructed. If these checks do not reveal the cause, call your servicing
dealer.
If your unit is not operating at all, check the following list for easy
solutions:
( ) Check to be sure that your thermostat temperature selector is set
below the indoor temperature during the cooling season or above the
indoor temperature during heating season. Be sure the SYSTEM switch
or MODE control is in the COOL or HEAT and not OFF.
( ) If your unit still fails to operate, call your servicing dealer for
troubleshooting and repairs. Specify the model and serial numbers of
Table
2)
your unit. (Record them in this manual in the space provided.) If the
dealer knows exactly which unit you have, he may be able to offer
suggestions over the phone, or save valuable time through
knowledgeable preparation for the service call.
In Case of Trouble
If you perform the steps above and unit performance is still
unsatisfactory, shut off the unit and call your dealer.