Float Switch Installation - Simer 2883 Owner's Manual

Submersible cast iron and zinc sump pump
Table of Contents

Advertisement

Available languages

Available languages

Installation

Float Switch Installation

Models equipped with vertical switches require some
assembly. See below.
For parts or assistance, call Simer Customer Service at
Installation
1. Install pump in sump pit with minimum diameter
of 10" (254mm) for models equipped with vertical
switches and 14" (356mm) for tethered float switch
models. Sump depth should be 16" (406mm) for
tethered models and 10" (254mm) for vertically
switched models. Construct sump pit of tile, concrete,
steel or plastic. Check local codes for approved
materials and for proper installation.
2. Install pump in pit so that switch operating
mechanism has maximum possible clearance.
3. Pump should not be installed on clay, earth or sand
surfaces. Clean sump pit of small stones and gravel
which could clog pump. Keep pump inlet screen clear.
NOTICE Do not use ordinary pipe joint compound on
plastic pipe. Pipe joint compound can attack plastics.
4. Install discharge plumbing. Use rigid plastic pipe and
wrap threads with PTFE pipe thread sealant tape.
6765 0213
Screw pipe into pump hand tight plus 1-1/2 turns.
and/or property damage. If a flexible discharge hose is
used, make sure pump is secured in sump to prevent
movement. Failure to secure pump may allow pump
movement, switch interference and prevent pump from
starting or stopping.
Risk of flooding. Can cause personal injury
800-468-7867
3
4827 0205

Advertisement