Wolverine Basic Pump Repair
Disconnect Pump
1. Follow Pressure Relief Procedure, page 22.
2. Expose the packing nut (37) by rotating the dust
cover (15) and sliding down when loose.
F
. 14 Expose packing nut
IG
28
2
1
3. Loosen, but do not remove, the packing nut (37).
37
F
. 15 Loosen packing nut
IG
15
4. Expose the cam (8) by loosening the cap screws
(27) and removing the molded guard (26). The cap
screws will remain with the molded guard.