Potterton Ultra 30 Installation & Servicing Manual page 7

Ultra range of wall mounted fan assisted balanced flue gas boilers
Table of Contents

Advertisement

GENERAL - PAGE 7
Fig. 1
Dimension
A
B
C
D
E
F
G
H
I
J
K
L
M
*If the terminal is fitted within 850 mm of a plastic or painted gutter/pipe or 450 mm of painted eaves, an aluminium
shield of at least 750 mm in length should be fitted to the underside of the gutter/pipe or painted surface.
**If the terminal is fitted less than 2 m above a balcony, above ground or above a flat roof to which people have
access then a suitable terminal guard must be provided and fitted.
A type K1 (G.C. No. 393 552) protective guard is available from Tower Flue Components Ltd. at: Vale Rise, Tonbridge, Kent TN9 1TB,
Tel: 0732 351555.
The guard must be securely fitted to the wall and centrally located over the flue terminal. Refer to the manufacturers instructions.
Supplied By www.heating spares.co Tel. 0161 620 6677
Terminal Position (Fanned Balanced Flue models)
Directly below an opening, air brick, window, etc.
Below gutters, soil pipes or drain pipes
Below eaves
Below balconies or car port roof
From a vertical drain pipe or soil pipe
From an internal corner
From an external corner
Above ground, roof or balcony level
From a surface facing the terminal
From a terminal facing the terminal
From an opening in the car port (e.g. door, window) into dwelling
Vertically from a terminal on the same wall
Horizontally from a terminal on the same wall
Min. Spacing
300
75 *
200 *
200
75
25
25
300 **
600
1200
1200
1500
300