Repair Instructions
4
Carefully remove the power switch using a flat
screwdriver or similar tool. See Figure 4
Fig 4
5
Check that the contact plate in the power switch is
intact and free of dirt and oxidation. See Figure 5.
Clean and assemble the power switch. Carry out a
resistance test according to step 2.
Fig 5
6
Loosen the cables and remove the cable bracket.
See Figure 6.
Fig 6