Toshiba RAS-M07N4KVRG-E Service Manual page 86

Air-conditioner multiple type
Table of Contents

Advertisement

11-6-3. Indoor Unit (Other Parts)
No.
Part name
1
Room temp. (TA) sensor
Heat exchanger (TC, TCJ)
sensor
2
Remote controller
3
Louver motor
24BYJ48-ST
MSBPC20F04
4
Indoor fan motor
Disconnect the connector and measure the resistance value with tester.
(Normal temp.)
Temperature
Sensor
TA, TC, TCJ (kΩ)
Refer to 11-5-1. (5).
Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)
White
1
1
Yellow
2
2
Yellow
3
3
Yellow
4
4
Yellow
5
5
Refer to 11-5-1. (3) and (4).
- 86 -
Checking procedure
10°C
20°C
25°C
20.7
12.6
10.0
Position
1 to 2
1 to 3
1 to 4
1 to 5
30°C
40°C
7.9
4.5
Resistance value
24BYJ48-ST
200Ω ± 7%
MSBPC20F04
250Ω ± 7%
at 25°C