Panasonic VL-SV70 Installation Manual page 6

Video intercom system
Hide thumbs Also See for VL-SV70:
Table of Contents

Advertisement

Wire type and length
Wiring run
Doorphone –
Main monitor
Main monitor –
*2
Electric lock
Main monitor –
Connection device for
option input (A contact)
*1 Type: Single-pair cable with outer sheath (jacket)
Conductor: Copper solid
R A certified power supply wiring has to be used with this equipment. The relevant national
installation and/or equipment regulations shall be considered. A certified power supply wiring not
lighter than ordinary polyvinyl chloride flexible wiring according to IEC 60227 shall be used.
*2 When using an electric lock or a connection device for option input (A contact), select a device that
meets the following guidelines:
R Electric lock connection terminal (S1/S2):
– N/O dry closure contact
– 30 V AC (1 A)/24 V DC (1 A) or lower
R Connection device for option input (A contact) terminal (IN1/IN2):
– Input method: No-voltage contact
– Open-circuit voltage between terminals: DC 7 V or less
– Detection definite time: 0.1 second or more
– Short-circuit between terminals: 5 mA or less
– Resistance value: make: 500 W or less, break: 15 KW or more
6
ø 0.65 mm
ø 1.0 mm
ø 0.5 mm
ø 0.5 mm - ø 1.2 mm
(24 AWG - 17 AWG)
ø 0.5 mm - ø 1.2 mm
(24 AWG - 17 AWG)
*2
Wire type
Diameter
22 AWG
18 AWG
CAT 5
*1
Length (Max.)
100 m
130 m
50 m
According to the
specifications of the
connected device.
According to the
specifications of the
connected device.

Advertisement