Fujitsu AS G07LLCC Series Service Manual page 58

Hide thumbs Also See for AS G07LLCC Series:
Table of Contents

Advertisement

MODEL : ASYG07LLCD, ASYG09LLCD, ASYG12LLCD
This procedure changes to the function settings used to control the indoor unit
according to the installation conditions.
Incorrect settings can cause the indoor unit malfunction.
After the power is turned on, perform the "FUNCTION SETTING" according to
the installation conditions using the remote controller.
Settings will not be changed if invalid numbers or setting values are selected.
Entering the Function Setting Mode
While pressing the FAN button and SET TEMP.( ) button simultaneously,
press the RESET button to enter the function setting mode.
Selecting the Function Number and Setting Value
(1) Press the SET TEMP.( ) ( ) buttons to select the function number.
(Press the POWERFUL button to switch between the left and right digits.)
(2) Press the FAN button to proceed to setting the value.
(Press the FAN button again to return to the function number
selection.)
(3) Press the SET TEMP.( ) ( ) buttons to select the setting value.
(Press the POWERFUL button to switch between the left and right digits.)
(4) Press the MODE button, in the order listed to confirm the setting.
Please confirm that the beep sounds.
(5) Next, please press the START/STOP(
Please confirm that the beep sounds.
(6) Press the RESET button to cancel the function setting mode.
(7) After completing the FUNCTION SETTING, be sure to turn off the
power and turn it on again.
After turning off the power, wait 10 seconds or more
before turning on it again.
The FUNCTION SETTING doesn't become active unless
the power is turned off then on again.
) button.
CAUTION
03-06
Function
Number
Setting Value

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents