7.3.4.
PREPARATION
1. Connect the Interface Box to the TP Board Kit with Camera Connecting cable (VFKW1000B).
2. Connect the Interface Box to the Personal Computer with RS-232C cable (VFKW1000C or VFKW1000D).
3. Connect the TP Board Kit to S301 on the camcorder. Refer to "HOW TO USE TP BOARD KIT" in "SERVICE NOTES."
4. Connect the AC Adaptor and camcorder, and apply
DC +6 V to the Interface Box.
5. Power on the camcorder.
Note:
In case that the camcorder is in DEMO mode, release DEMO mode as follows:
Power off the camcorder first. Then, disconnect the TP Board Kit, and power on the camcorder. Then, press the STOP
button over 5 seconds.
CAUTION:
a. Do not connect or disconnect any cables while the camcorder is powered on.
b. Before using the TP Board Kit, be sure to clean S301 pattern with alcohol and confirm that there is no dust in the
TP Clip.
c. To achieve the best adjustment results, warm up the camcorder for approx. 30 minutes before adjustment.
d. When removing the TP Clip from S301 on the camcorder, be sure to pinch the grips.
6. Set up the camcorder for adjustment as follows:
Fig. E2-1