• Heating mode
Model name
AOYG09KATA
AOYG12KATA
AOYG14KATA
AOYG18KATA
1-5. Compressor frequency limitation by outdoor temperature
F zone
19°C
E zone
5°C
D zone
0°C
C zone
-15°C
B zone
-25°C
A zone
Outdoor temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
A zone
B zone
C zone
D zone
E zone
F zone
A zone
B zone
C zone
D zone
E zone
F zone
A zone
B zone
C zone
D zone
E zone
F zone
- (01-7) -
Limitation of compressor
frequency
43 rps
43 rps
30 rps
18 rps
16 rps
16 rps
43 rps
43 rps
30 rps
18 rps
16 rps
16 rps
37 rps
37 rps
36 rps
15 rps
1 rps
1 rps
37 rps
37 rps
36 rps
15 rps
1 rps
1 rps