7.3.7 To remove the discharge grille, and put the grille in safety position
EPRA08~12EAV3+W1 + ETVH/X12S18+23EA6V+9W
Daikin Altherma 3 H MT F
4P634886-1 – 2021.03
9 Fix the 6 remaining screws.
9
6×
5 N•m
WARNING
Rotating fan. Before powering ON or servicing the outdoor unit, make sure that the
discharge grille covers the fan as protection against a rotating fan. See:
▪
"7.3.6 To install the discharge
▪
"7.3.7 To remove the discharge grille, and put the grille in safety
1 Remove the upper part of the discharge grille.
4×
2 Remove the lower part of the discharge grille.
7
|
8
7
4
grille" [
75]
Unit installation
4
position" [
77]
Installer reference guide
77