Overview Of Electrical Connections Except External Actuators; Connections To The Outdoor Unit - Daikin EPRA08EAV3 Installer's Reference Manual

Table of Contents

Advertisement

9
|
Electrical installation

9.1.6 Overview of electrical connections except external actuators

9.2 Connections to the outdoor unit

Installer reference guide
100
Normal power supply
a
0
0
58 0
1 5 0
3
1
2
a Normal power supply
b Preferential kWh rate power supply
1 Power supply for outdoor unit
2 Power supply and interconnection cable to indoor unit
3 Power supply for backup heater
4 Preferential kWh rate power supply (voltage free contact)
5 Normal kWh rate power supply (to power the indoor unit PCB in
the event of power supply interruption of the preferential kWh
rate power supply)
Item
Power supply cable
Interconnection cable
Drain tube heater cable
Connection for power
saving function (only for V3
models)
Preferential kWh rate power supply
Power supply is NOT
interrupted
b
0
0
58 0
1 5 0
3
1
4
2
During preferential kWh
rate power supply
activation, power supply
is NOT interrupted. The
outdoor unit is turned off
by the control.
Remark: The electricity
company must always
allow the power
consumption of the
indoor unit.
Description
See
"9.2.1 To connect the electrical wiring to the
4
outdoor
unit" [
 101].
EPRA08~12EAV3+W1 + ETVH/X12S18+23EA6V+9W
Power supply is
interrupted
a
b
0
0
0
0
58 0
58 0
1 5 0
1 5 0
5
3
4
1
2
During preferential kWh
rate power supply
activation, power supply
is interrupted
immediately or after
some time by the
electricity company. In
this case, the indoor unit
must be powered by a
separate normal power
supply.
Daikin Altherma 3 H MT F
4P634886-1 – 2021.03

Advertisement

Table of Contents
loading

Table of Contents