To reduce the risk of injury, user must read and understand operator's manual before using this
generator.
DANGER:
You WILL be KILLED or SERIOUSLY HURT if you do not follow the instructions in this operator's
manual.
Pour réduire les risques de blessures, l'utilisateur doit lire et veiller à bien comprendre le manuel
d'utilisation avant d'utiliser ce groupe.
DANGER :
Le non-respect des instructions fournies dans ce manuel d'utilisation entraînera des BLESSURES
GRAVES, voire MORTELLES.
Para reducir el riesgo de lesiones, el usuario debe leer y comprender el manual del operador antes de
usar este generador.
PELIGRO:
El incumplimiento de las instrucciones en este manual del operador puede CAUSARLE LA MUERTE
O LESIONARLE GRAVEMENTE.
R
SAVE THIS MANUAL FOR FUTURE REFERENCE
CONSERVER CE MANUEL POUR FUTURE RÉFÉRENCE
GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS
Customer serviCe
serviCe CLieNteLe
serviCio AL CLieNte
1-800-726-5760

Advertisement

Table of Contents
loading

Summary of Contents for Black Max BM10500 Series

  • Page 1 Serie BM10500 to register your Black max product, please visit: www.blackmaxtools.com Pour enregistrer votre produit de Black max, s’il vous plaît la visite: www.blackmaxtools.com Para registrar su producto de Black max, por favor visita: www.blackmaxtools.com To reduce the risk of injury, user must read and understand operator’s manual before using this generator.
  • Page 2 See this fold-out section for all of the figures referenced in the operator’s manual. Consulter l’encart à volets afin d’examiner toutes les figures mentionnées dans le manuel d’utilisation. Consulte esta sección desplegable para ver todas las figuras a las que se hace referencia en el manual del operador.
  • Page 3 Fig. 1 Fig. 2 A - Extension cord (cordon prolongateur, cordón de extensión) B - Twist-lock plug (prise à verrouillage, enchufe de bloqueo de giro) C - Receptacles (prises, receptaculos) G - 120 volt AC 20 amp receptacles (prises 120 V C.A.
  • Page 4 Fig. 4 Fig. 10 Fig. 7 A - Oil cap/dipstick (bouchon/ jauge d’huile, tapa de relleno de aceite/varilla medidora de aceite) A - Frame (cadre, armazón) B - Oil fill hole (orifice de remplissage d’huile, B - Handle (poignée, mango) A - Bolt (boulon, perno) agujero de llenado de aceite) C - Hole (trou, agujero)
  • Page 5 Fig. 13 Fig. 16 Fig. 19 A - Fuel line (conduite de carburant, conducto de combustible) B - Fuel valve (robinet de carburant, válvula de combustible) A - Fuel valve (robinet de carburant, válvula de C - Petcock (robinet de carburant, llave de combustible) A - Oil drainage bolt (vis de vidange d’huile, purga)
  • Page 6: Table Of Contents

    TABLE OF CONTENTS  Introduction ..................................2  Important Safety Instructions .............................3-4  Specific Safety Rules ..............................4  Symbols ..................................5-7  Electrical ..................................8-9  Features ..................................10  Assembly ................................11-12  Operation ................................13-14  Maintenance ................................15-17  Troubleshooting ................................18 ...
  • Page 7: Important Safety Instructions

    IMPORTANT SAFETy INSTRUCTIONS  Keep all bystanders, children, and pets at least 10 feet away. DANGER:  Wear sturdy and dry shoes or boots. Do not operate while Carbon Monoxide. Using a generator indoors WILL KILL barefoot. YOU IN MINUTES. ...
  • Page 8: Specific Safety Rules

    IMPORTANT SAFETy INSTRUCTIONS  Maintain the unit per maintenance instructions in this  Inspect the unit before each use for loose fasteners, fuel Operator’s Manual. leaks, etc. Replace damaged parts. SPECIFIC SAFETy RULES  Do not connect to a building’s electrical system unless a transfer switch has been properly installed by a qualified WARNING: electrician.
  • Page 9: Symbols

    SyMBOLS Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the product better and safer. SyMBOL NAME DESIGNATION/EXPLANATION Volts Voltage Amperes Current Hertz Frequency (cycles per second)
  • Page 10 SyMBOLS The following signal words and meanings are intended to explain the levels of risk associated with this product. SyMBOL SIGNAL MEANING Indicates an imminently hazardous situation, which, if not avoided, will result DANGER: in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, could result WARNING: in death or serious injury.
  • Page 11 SyMBOLS SAFETy LABELS DANGER PELIGRO Generator is a potential source of electric shock. Do not expose to Failure to properly ground generator can result in electrocution, You WILL be KILLED or SERIOUSLY HURT if you do not The information on this page can be found follow the Operator’s Manual instructions.
  • Page 12: Electrical

    ELECTRICAL EXTENSION CORD CABLE SIzE Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load. Inadequate size cables can cause a voltage drop, which can burn out the appliance and overheat the cord. Load in Watts Maximum Allowable Cord Length Current in...
  • Page 13 ELECTRICAL GENERATOR CAPACITy CAUTION: Make sure the generator can supply enough continuous (run- Do not overload the generator’s capacity. Exceeding the ning) and surge (starting) watts for the items you will power generator’s wattage/amperage capacity can damage the at the same time. Follow these simple steps. generator and/or electrical devices connected to it.
  • Page 14: Features

    FEATURES PRODUCT SPECIFICATIONS GENERATOR ENGINE Engine Type ......4 Stroke, OHC (Chain Drive) Rated Voltage .............120V/240V Rated Amps ............. 41.6A/20.8A Bore x Stroke ..........75 mm x 65 mm Rated Output ............5,000 W Cooling System ...........Forced Air Maximum Output............6,250 W Compression Ratio ............
  • Page 15: Assembly

    ASSEMBLy WARNING: WARNING: Do not attempt to operate the generator until assembly If any parts are damaged or missing do not operate this product until the parts are replaced. Failure to heed is complete. Failure to comply could result in possible serious personal injury.
  • Page 16 ASSEMBLy INSTALLING THE WHEELS SECURING THE HANDLE See Figure 5. See Figures 6 - 9. Wheels are provided to assist in moving the generator to  Locate the following items: the desired location and should be installed on the side Handle opposite the handle.
  • Page 17: Operation

    OPERATION  NEVER use inside a home or garage, EVEN IF doors and windows are open. DANGER: Carbon Monoxide. Using a generator indoors WILL KILL  Always position the generator on a flat firm surface. YOU IN MINUTES. CAUTION: Generator exhaust contains high levels of carbon mon- Attempting to start the engine before it has been properly oxide (CO), a poisonous gas you cannot see or smell.
  • Page 18 OPERATION OXyGENATED FUELS STARTING THE ENGINE See Figures 12 - 14. Some conventional gasolines are blended with alcohol or an ether compound. These gasolines are collectively referred NOTE: If location of generator is not level, the unit may not to as oxygenated fuels. To meet clean air standards, some start or may shut down during operation.
  • Page 19: Maintenance

    NOTE: Used lubricant should be disposed of at an ap- WARNING: proved disposal site. See your local oil retailer for more information. When servicing, use only identical Black Max replace- ment parts. Use of any other parts may create a hazard SPARK PLUG MAINTENANCE or cause product damage.
  • Page 20 MAINTENANCE DRAINING FUEL TANK/CARBURETOR DRAINING THE CARBURETOR See Figures 19 - 20.  Turn the engine switch OFF ( O ). To help prevent gum deposits in the fuel system, drain the  Turn the fuel valve to the OFF position. fuel from the tank and carburetor before storing.