Correct Use; How To Replace The Wire Coil - Kyocera TJEP 40 Manual

Ultr a grip
Hide thumbs Also See for TJEP 40:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 85
10. Adjusting the wraps
By default the machine is set for 3 wraps (ULTRA
GRIP 58: 4 wraps). Changing the setting to 2 wraps
(ULTRA GRIP 58: 3 wraps): Turn off the machine
on the main switch. Press and hold the trigger while
turning on the main switch. The machine is now set
for 2 wraps per tie (ULTRA GRIP 58: 3 wraps). If the
machine is turned off, it will automatically be set for 3
wraps again (ULTRA GRIP 58: 4 wraps).
11. The torque setting unit adjusts the tension of the
ties. 1. digit displays the wrap setting and 2. digit dis-
plays the torque setting. The torque can be adjusted
higher
or lower
by means of the push buttons.
We recommend:
Model
2 wraps
ULTRA GRIP 25
1 - 5
ULTRA GRIP 40
1 - 5
ULTRA GRIP 58
-
12. Perform a test tie, to check if the torque is set
correctly.

Correct use

1. Place the arm A unit in a 45° angle over the re-bar
cross surface and push the mouth towards the re-bar.
45°
2. Place Arm A perpendicularly on top of the re-bar
cross surface and with the mouth centred over the
cross.
3 wraps
4 wraps
6 - 9
-
6 - 9
-
1 - 5
6 - 9
!
WARNING! Do not move the re-bar binder
!
while it is tying.
3. The ties should be made in alternating directions.
4. Cross-tying.
Bend down the knot of the first tie, before you make
the second tie.

How to replace the wire coil.

WARNING! Set the main switch to OFF po-
!
sition, activate the trigger lock and remove
the battery.
1. Push the release lever until it is caught by the
release stopper.
Release lever
Release stopper
2. Remove the wire coil.
Pipe
English
Wire
89

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Tjep 25Tjep 58

Table of Contents