1-5. Compressor frequency limitation by outdoor temperature

The minimum compressor frequency is limited by outdoor temperature as below.
• Cooling/Dry mode
Model name
AOYG24KATA
• Heating mode
Model name
AOYG24KATA
1-5. Compressor frequency limitation by outdoor temperature
F zone
38°C
E zone
19°C
D zone
10°C
C zone
0°C
B zone
-10°C
A zone
Outdoor temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
F zone
19°C
E zone
5°C
D zone
0°C
C zone
-15°C
B zone
-25°C
A zone
Outdoor temperature zone
A zone
B zone
C zone
D zone
E zone
F zone
- (04-4) -
Limitation of compressor
frequency
33 rps
33 rps
31 rps
19 rps
1 rps
20 rps
Limitation of compressor
frequency
31 rps
31 rps
21 rps
13 rps
1 rps
1 rps