Texas Instruments INA260 User Manual page 11

Evaluation module and product demonstration kit
Table of Contents

Advertisement

www.ti.com
2.2.2
EVM Analog Inputs
The INA260 accepts two kinds of analog inputs: namely, a current through the internal shunt resistor and
a voltage between the V
one or both of these inputs in serial order. The high current lug connectors designated T1 and T2 are the
terminations of the internal 2-mΩ shunt resistor. Therefore, connect T1 and T2 in series with the input
current source and load; see
through the shunt resistor in either direction.
Do Not Exceed the Absolute Maximum Ratings (see the
datasheet)!
To help ensure safe operating conditions, the following electrical ratings must
not be exceeded:
15 A between connectors T1 and T2 in either direction
36 Vdc between T1 and GND
36 Vdc between T2 and GND
Potential Burn Hazard!
To minimize risk of burn, do not touch U1 (the INA260 device)
when input current is present. Temperatures higher than 50°C are
possible.
The V
input of the INA260 is accessible through pin 2 of header J1. Pins 1 and 3 of J1 are connected
BUS
to IN+ and IN–, respectively. Note that the V
input can be applied with or without a load), and the INA260 provides an accurate voltage reading.
However, the device also passively multiplies the measured values of V
power value. For the power calculation to be meaningful, V
the input current across the load. Therefore, for accurate load power measurements, short the V
IN+ or IN– (on header J1) depending on the location of the load. For example, for the arrangement in
Figure
3, short V
BUS
The EVM PCB also includes placeholders for the TVS devices to protect the INA260 inputs from
excessively high common-mode voltages. The pads for these uninstalled devices, D3 and D4, are located
on the bottom side of the EVM PCB and are suitable for DO-214AB package.
SBOU180 – November 2016
Submit Documentation Feedback
pin and GND. The GUI allows the INA260 to be configured for digitizing either
BUS
Figure
3. The INA260 is a bidirectional device and thus current can flow
BUS
to IN– for an accurate load power calculation.
Copyright © 2016, Texas Instruments Incorporated
CAUTION
WARNING
input is independent of the current input (that is, the V
must represent the voltage drop created by
BUS
INA260EVM-PDK and Software Tutorial
INA260EVM-PDK Hardware
INA260
and input current to generate a
BUS
BUS
BUS
pin to
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ina260evm-pdk

Table of Contents