Mitsubishi Electric FR-E720-0.1 K Instruction Manual page 72

Table of Contents

Advertisement

Parameter list
Func-
Parameter
Name
tion
PID control automatic switchover
127
frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
145
PU display language selection
146
∗7
Built-in potentiometer switching
Acceleration/deceleration time
147
switching frequency
150
Output current detection level
Output current detection signal delay
151
time
152
Zero current detection level
153
Zero current detection time
156
Stall prevention operation selection
157
OL signal output timer
160
User group read selection
Frequency setting/key lock operation
161
selection
Automatic restart after instantaneous
162
power failure selection
Stall prevention operation level for
165
restart
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
User group registered display/batch
172
clear
173
User group registration
174
User group clear
178
STF terminal function selection
179
STR terminal function selection
180
RL terminal function selection
181
RM terminal function selection
182
RH terminal function selection
183
MRS terminal function selection
184
RES terminal function selection
64
Minimum
Refer
Initial
Setting Range
Setting
to
Value
Increments
Page
0 to 400Hz, 9999
0.01Hz
9999
236
0, 20, 21, 40 to 43,
236,
1
0
50, 51, 60, 61
243
236,
0.1 to 1000%, 9999
0.1%
100%
243
236,
0.1 to 3600s, 9999
0.1s
1s
243
236,
0 to 100%, 9999
0.1%
9999
243
236,
0 to 100%, 9999
0.1%
9999
243
236,
0 to 100%, 9999
0.01%
9999
243
236,
0.01 to 10.00s, 9999
0.01s
9999
243
0 to 7
1
0
261
0, 1
1
1
266
0 to 400Hz, 9999
0.01Hz
9999
105
0 to 200%
0.1%
150%
145
0 to 10s
0.1s
0s
145
0 to 200%
0.1%
5%
145
0 to 1s
0.01s
0.5s
145
0 to 31, 100, 101
1
0
88
0 to 25s, 9999
0.1s
0s
88
0, 1, 9999
1
0
183
0, 1, 10, 11
1
0
262
0, 1, 10, 11
1
1
157
0 to 200%
0.1%
150%
157
0, 10, 9999
1
9999
149
0, 9999
1
9999
149
9999, (0 to 16)
1
0
183
0 to 999, 9999
1
9999
183
0 to 999, 9999
1
9999
183
0 to 5, 7, 8, 10, 12,
14 to 16, 18, 24, 25,
1
60
134
60, 62, 65 to 67, 9999
0 to 5, 7, 8, 10, 12,
14 to 16, 18, 24, 25,
1
61
134
61, 62, 65 to 67, 9999
1
0
134
0 to 5, 7, 8, 10, 12,
1
1
134
14 to 16, 18, 24, 25,
1
2
134
62, 65 to 67, 9999
1
24
134
1
62
134
Customer
Parameter
Remarks
Setting
127
128
129
130
131
132
133
134
145
146
147
150
151
152
153
156
157
160
161
162
165
168
Parameter for manufacturer setting. Do not set.
169
170
171
172
173
174
178
179
180
181
182
183
184
Control Mode-based
Instruction Code
Correspondence Table
Read
Write
Extended
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
1B
9B
1
1C
9C
1
1D
9D
1
1E
9E
1
1F
9F
1
20
A0
1
21
A1
1
22
A2
1
2D
AD
1
2E
AE
1
2F
AF
1
32
B2
1
33
B3
1
34
B4
1
35
B5
1
38
B8
1
39
B9
1
00
80
2
01
81
2
02
82
2
05
85
2
0A
8A
2
0B
8B
2
0C
8C
2
0D
8D
2
0E
8E
2
12
92
2
13
93
2
14
94
2
15
95
2
16
96
2
17
97
2
18
98
2
Parameter list
Parameter
Copy
Clear
All clear
×
×
×
×
×
×
4
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents