Indoor Fan Control - Fujitsu AU G24LVLA Series Service Instruction

Hide thumbs Also See for AU G24LVLA Series:
Table of Contents

Advertisement

1-5. INDOOR FAN CONTROL

1. Fan speed
( Table 5 : Indoor Fan Speed )
*Note, during Economy operation and operation mode is Fan, air flow is 1 step downs.
(Hi > Me, Me > Lo, Lo > Quiet, Quiet > Soft Quiet)
AB*G24LVTA
Operation mode
Air flow mode
Hi
Heating
Me+
Me
Lo
Quiet
Cool air prevention
S-Lo
Hi
Cooling
Me
Fan
Lo
Quiet
*Soft Quiet
Auto
Dry
S-Lo
Monitoring
AR*G24LMLA
Operation mode
Air flow mode
Hi
Heating
Me
Lo
Quiet
S-Lo
Hi
Cooling
Me
Fan
Lo
Quiet
*Soft Quiet
Auto
Dry
S-Lo
Monitoring
AU*G24LVLA
Operation mode
Air flow mode
Hi
Heating
Me+
Me
Lo
Quiet
Cool air prevention
S-Lo
Hi
Cooling
Fan
Me
Lo
Quiet
*Soft Quiet
Dry
Auto
S-Lo
Monitoring
01-05
Speed (rpm)
1300
1200
1150
1000
780
500
300
1330
1150
1000
780
500
780
300
Speed (rpm)
830
700
600
550
350
830
700
600
550
350
550
350
Speed (rpm)
960
930
880
740
580
400
300
960
850
650
500
400
500
300

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar g24lmla seriesAb g24lvta seriesAo g24lala series

Table of Contents