Errata and Supplementary Notes
Regretfully a number of inaccuracies appear in the Owner's Manual for the Digital Snake S-4000. It should read as shown
below. We apologize for any inconveniences this may cause.
page 1(cover), 20, 40, 50, 61, 72
++
incorrect
www.RSSAmerica.com
Specifications: S-4000S 40 CH I/O MODULAR RACK
Operation Temperature:
++
incorrect
+10 to +35 degrees Celsius
+50 to +95 degrees Fahrenheit
Specifications: S-4000H 32x8 FOH UNIT
Operation Temperature:
++
incorrect
+10 to +35 degrees Celsius
+50 to +95 degrees Fahrenheit
Specifications: S-4000R REMOTE CONTROLLER
Operation Temperature:
++
incorrect
+10 to +35 degrees Celsius
+50 to +95 degrees Fahrenheit
Caution: in case audio output from S-4000 system is connected to
external devices
When audio outputs from an S-4000S or an S-4000H are connected to inputs of external devices such as mixing consoles,
please be sure to turn off the phantom power supply from these external devices.
Noise may come out while [MUTE ALL OUTPUTS] is pressed and all outputs are muted if phantom power is supplied
from the external device.
Caution: in case Switching Hub is integrated in the system
The device-to-device transmission latency between REAC devices is approx 375 micro seconds.
If switching hubs are integrated in the system and data is transferred via the switching hubs, approx 200 micro seconds
of latency will be added for each switching hub.
should read
➔
www.roland.com
should read
➔
0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit
should read
➔
0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit
should read
➔
0 to +40 degrees Celsius
+32 to +104 degrees Fahrenheit