Declared noise emissions

Declared noise emissions in accordance with ISO 9296

Table 1. Declared noise emissions in accordance with ISO 9296
Product description
Models: A00, A01, A02, M01
@ 25 deg. C room ambient
Models: A00, A01, A02, M01
@ 35 deg. C room ambient
Models: A00, A01, A02, M01
@ 25 deg. C room ambient
Acoustical Doors Feature codes
FC EC07 = back FC EC08 = front
Models: A00, A01, A02, M01
@ 35 deg. C room ambient
Acoustical Doors Feature codes
FC EC07 = back FC EC08 = front
Notes:
1. Declared level L
is the upper-limit A-weighted sound power level; Declared level L
WAd
A-weighted sound pressure level measured at the 1-meter bystander positions.
2. All measurements made in conformance with ISO 7779 and declared in conformance with ISO 9296.
3. B, dB, abbreviations for bels and decibels, respectively. 1 B = 10 dB.
4.
Note: Government regulations (such as those prescribed by OSHA or European Community Directives) may
govern noise level exposure in the workplace and may apply to you and your server installation. This IBM
system is available with an optional acoustical door feature that can help reduce the noise emitted from this
system. The actual sound pressure levels in your installation depend upon a variety of factors, including the
number of racks in the installation; the size, materials, and configuration of the room where you designate the
racks to be installed; the noise levels from other equipment; the room ambient temperature, and employees'
location in relation to the equipment. Further, compliance with such government regulations also depends upon
a variety of additional factors, including the duration of employees' exposure and whether employees wear
hearing protection. IBM recommends that you consult with qualified experts in this field to determine whether
you are in compliance with the applicable regulations.
(1, 2, 3)
(1,2,3)
Declared A-Weighted
Sound Power Level,
L
(B)
WAd
Operating
Idling
(4)
7.2
6.8
(4)
(4)
7.2
7.2
6.6
6.2
6.6
6.6
Declared A-Weighted
Sound Pressure Level,
L
(dB)
pAm
Operating
Idling
56
52
56
56
49
45
49
49
is the mean
pAm