Troubleshooting; Error Indication; Relationship Between - SMC Networks ISA3-GCP-M1LB-L1 Operation Manual

Digital gap checker
Table of Contents

Advertisement

Error indication

Main screen
Error Name
Supply pressure error
Display value outside of
the displayable range
(Switch point setting
mode)
OUT1 over current error
Zero clear error
System error
Sub screen
Error Name
Supply pressure error
(When pressure is
displayed on the sub
screen)
Relationship between supply pressure and display
Description
Displayed when supply pressure is
less than 80 kPa or more than 220
kPa.
Measurement is not possible.
The workpiece is outside the
displayable range.
The switch output (OUT1) load
current has exceeded 80 mA.
Zero clear was performed in
non-atmospheric pressure
(Pressure outside of ±14 kPa was
supplied present.)
An internal data error has occurred.
Description
Pressure exceeding 220 kPa is
supplied.
Vacuum pressure (-20 kPa or less) is
supplied.
-62-
5

Troubleshooting

Measures
Supply rated pressure. (100 kPa to
200 kPa)
The product will return to
measurement mode automatically.
Move the workpiece closer to the
detection nozzle.
Turn the power OFF and remove the
cause of the over current. Then turn
the power ON again.
Perform zero clear at atmospheric
pressure.
Turn the power OFF and turn it ON
again.
Measures
Keep the supply pressure within the
display range of -20 kPa to 220 kPa.
No.PS※※-OMR0002-K