System Realtime Message; System Exclusive Message - Roland V-Synth XT Supplementary Manual

Midi implementation
Hide thumbs Also See for V-Synth XT:
Table of Contents

Advertisement

● MONO (Controller number 126)
Status
2nd byte
BnH
7EH
n = MIDI channel number:
0H - FH (ch.1 - 16)
mm = mono number:
00H - 10H (0 - 16)
* The same processing will be carried out as when All Notes Off is received.
● POLY (Controller number 127)
Status
2nd byte
BnH
7FH
n = MIDI channel number: 0H - FH (ch.1 - 16)
* The same processing will be carried out as when All Notes Off is received.

■ System Realtime Message

● Active Sensing
Status
FEH
* When Active Sensing is received, the unit will begin monitoring the intervals of all
further messages. While monitoring, if the interval between messages exceeds 420 ms,
the same processing will be carried out as when All Sounds Off, All Notes Off and Reset
All Controllers are received, and message interval monitoring will be halted.

■ System Exclusive Message

Status
Data byte
F0H
iiH, ddH, ......,eeH
F0H:
System Exclusive Message status
ii = ID number:
an ID number (manufacturer ID) to indicate the manufacturer whose
Exclusive message this is. Roland's manufacturer ID is 41H.
ID numbers 7EH and 7FH are extensions of the MIDI standard;
Universal Non-realtime Messages (7EH) and Universal Realtime
Messages (7FH).
dd,...,ee = data:
00H - 7FH (0 - 127)
F7H:
EOX (End Of Exclusive)
Of the System Exclusive messages received by this device, the Universal Non-realtime
messages and the Universal Realtime messages and the Data Request (RQ1) messages and
the Data Set (DT1) messages will be set automatically.
● Universal Non-realtime System Exclusive Messages
❍ Identity Request Message
Status
Data byte
F0H
7EH, dev, 06H, 01H F7H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal Non-realtime Message)
dev
Device ID (dev: 10H - 1FH, 7FH)
06H
Sub ID#1 (General Information)
01H
Sub ID#2 (Identity Request)
F7H
EOX (End Of Exclusive)
* When this message is received, Identity Reply message (p. 6) will be transmitted.
3rd byte
mmH
3rd byte
00H
Status
F7H
Status
● Universal Realtime System Exclusive Messages
❍ Master Volume
Status
Data byte
F0H
7FH, 7FH, 04H, 01H, llH, mmH
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
01H
Sub ID#2 (Master Volume)
llH
Master Volume lower byte
mmH
Master Volume upper byte
F7H
EOX (End Of Exclusive)
* The lower byte (llH) of Master Volume will be handled as 00H.
* The Master Level parameter (SYSTEM Com Master) will change.
❍ Master Fine Tuning
Status
Data byte
F0H
7FH, 7FH, 04H, 03H, llH, mmH
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
03H
Sub ID#2 (Master Fine Tuning)
llH
Master Fine Tuning LSB
mmH
Master Fine Tuning MSB
F7H
EOX (End Of Exclusive)
mm, ll: 00 00H - 40 00H - 7F 7FH (-100 - 0 - +99.9 [cents])
* The Master Tune parameter (SYSTEM Com Master) will change.
❍ Master Coarse Tuning
Status
Data byte
F0H
7FH, 7FH, 04H, 04H, llH, mmH
Byte
Explanation
F0H
Exclusive status
7FH
ID number (universal realtime message)
7FH
Device ID (Broadcast)
04H
Sub ID#1 (Device Control)
04H
Sub ID#2 (Master Coarse Tuning)
llH
Master Coarse Tuning LSB
mmH
Master Coarse Tuning MSB
F7H
EOX (End Of Exclusive)
llH:
ignored (processed as 00H)
mmH:
28H - 40H - 58H (-24 - 0 - +24 [semitones])
* The Master Key Shift parameter (SYSTEM Com Master) will change.