TABLE 3 – OPERATION GUIDE
Condition
Solution
Condensation on
Reduce the setting on the control dial
windows.
by 1 increment.
Increase the setting on the control
dial by 1 increment. If the humidifier
control is already at the maximum
Lack of humidity.
setting of 7, set the Blower Activation
switch to ON. The humidifier should be
plumbed to hot water when using the
Blower Activation feature.
Turn dial to Test/Reset. Make certain
Humidifier does
HVAC blower is operating. If unit still
not operate.
does not operate, consult a heating
contractor.
Turn dial to OFF. If unit continues to
Humidifier will not
shut off.
operate, consult a heating contractor.
System operation is checked by
setting the knob to Test/Reset. Make
certain HVAC blower is operating.
Test mode.
Humidifier will operate for 1 minute.
NOTE: Placing the knob in Test/Reset
resets the water panel change timer.
Red Call Dealer
Note the error code on the display (E1,
for Service light
E2 or E3) and call your heating and air
flashes (FIGURE 1)�
conditioning dealer.
Refer to the Humidifier Owner's
manual for instructions on changing
the water panel or call your heating
Model 60 only:
and air conditioning dealer for
Yellow Change
service. After the water panel is
Water Panel light
replaced, turn the control knob to the
flashes (FIGURE 1)�
Test/Reset position until the green
Humidifier On light flashes. This will
reset the water panel change timer.
10
English
MANUAL HUMIDIFIER CONTROL
FIGURE 3 – MANUAL HUMIDIFIER CONTROL
Your AprilAire humidifier is controlled by a Manual
Humidifier Control (see FIGURE 3). The Manual
Humidifier Control is installed either in the cold air
return duct or on an interior wall of the home. With the
Manual Humidifier Control, it is important to anticipate
a drop in outdoor temperature and reduce the setting
accordingly to avoid excess condensation, just as with
the Digital Humidifier Control installed in Manual Mode
(see page 6).
To determine the indoor RH, slowly turn the knob
clockwise and counterclockwise and listen for 2 clicks.
The indoor RH is within the range of the 2 clicks. See
TABLE 2 on page 9.