Accu-Chek Active - Blood Glucose Meter Quick Reference Guide

Accu-Chek Active - Blood Glucose Meter Quick Reference Guide

Also See for Active:

Advertisement

Accu-Chek Active - Blood Glucose Meter Quick Reference Guide

Your unit at a glance

Your unit at a glance - Part 1

  1. Display
  2. S button (retrieving settings for time and date)
  3. Measuring window cover
  4. Measuring window (underneath the cover)
  5. Test strip guide
  6. M button (retrieving test results from the memory, changing time / date)
  7. Code chip
  8. Infrared window

Your unit at a glance - Part 2

  1. Code chip slot
  2. Code chip (inserted)
  3. Type plate
  4. Battery compartment
  5. Battery (type CR 2032)
  6. Locking catch for opening the battery compartment

Symbols at a glance

Symbols at a glance

  1. Memory or average
  2. Battery almost empty
  3. Settings: changing time and date
  4. With average being displayed: number of days covered
  5. Flashing: too much light
  6. Flashing: testing is in progress or average is being calculated
  7. General flag
  8. Unit of measurement for blood glucose result
  9. Test strips past their expiry date
  10. + 11. Flashing: test strip removed before blood was applie
  11. Flashing: prompt to apply blood to the test strip
  12. Code number display, flashing: code chip is missing
  13. After Meals flag
  14. Before Meals flag
  15. Temperature outside the permitted range
  16. Flag for performance check
  17. Add-on if time is in 12-hour format
  18. Symbols appearing in the numeric field:
Result lower than 10 mg/dL (0.6 mmol/L)
Result higher than 600 mg/dL (33.3 mmol/L)
+ flashing code code chip not correctly inserted into the meter or missing
+ memory average cannot be calculated

Error messages

Test strip not inserted correctly / completely; test strip removed and not re-inserted
Code chip from a different system
Code chip cannot be read; code chip from a different system
Measuring window dirty, test strip is bent / not positioned straight and flat
Used test strip inserted, measuring window dirty, test strip not inserted correctly / completely
Blood or control solution applied too early, test strip bent / moved, strong electromagnetic fi eld
Code chip removed while testing was in progress
Test strip bent / moved, test strip not inserted correctly / completely
Meter error
Too little blood or control solution applied
Temperature too low or too high for testing

warning This Quick Reference Guide does not replace the detailed Instructions for use for your Accu-Chek Active blood glucose meter. Please refer to the safety instructions contained in the Instructions for use.

Removing the protective film from the battery

Coding

Coding

Testing blood glucose

Testing blood glucose

Setting the time and date

Turning the meter on:
Press for more than 3 seconds.

Turning the meter off:
Press + briefly at the same time.

Changing settings:
Press or hold it down.

Confirming the change and continuing with the next setting:
Press briefly.


Order of the settings

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Accu-Chek Active - Blood Glucose Meter Quick Reference Guide

Advertisement

Need Assistance?

Do you have a question about the Active that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents