5.4.1
Scope of delivery
65
5
4
3
1
Wall collar, 100 dia-
meter (2 pcs)
2
Horizontal telescopic
wall duct
5.4.2
Installing the wall duct
1.
Drill a hole.
Diameter: 125 mm
Note
If the wall duct can be accessed from the
exterior of the building, you can drill the hole
with a diameter of 110 mm and install the
wall duct with the wall collar from outside.
1
2
2.
Determine the clearance to the external wall.
(→ Page 14)
3.
Set the telescopic wall duct to the correct length.
Note that the TOP symbol must point upwards on
both ends.
Danger!
Risk of poisoning due to escaping flue
gas.
Flue gas can escape if a flue pipe is dam-
aged.
Only use the self-tapping screw provided.
16
456-698
Ø167
1
2
3
40 mm clamp
4
87° elbow
5
30 mm clamp
1
4.
Secure the air pipes to each other by screwing the
overlapping air pipes together using the supplied self-
tapping screws on the underside (1).
5.
Seal the gap in the telescopic air pipe using the sup-
plied adhesive tape (2).
6.
Slide the air/flue pipe (1) with the flexible external collar
through the wall.
7.
Pull the air/flue pipe back until the external collar lies
fully on the external wall.
8.
Secure the air/flue pipe with mortar and leave the mor-
tar to harden.
9.
Install the wall collar on the inside of the wall.
10.
Connect the wall/roof duct to the product using ex-
tensions, elbows and, if required, a sliding sleeve.
(→ Page 16)
5.4.3
Installing the roof duct
Insert the air/flue pipe (1) without the external collar into
the dormer.
5.5
Connecting the product
1
2
3
7
6
Install the product (7) – see the installation instructions
1.
for the product.
2.
Connect the 87° elbow (1) to the connector for the
air/flue pipe (6).
3.
Fit the sliding sleeve (3) with the sleeve as far as it will
go onto the wall/roof duct (4) or the extension (5).
4.
If required, install the extensions .
5.
Connect the sliding sleeve to the 87° elbow.
6.
Install the air pipe clamp (2) for the sliding sleeve.
Alternatives 1:
7.
Condition: Wall/roof duct without extension
Install the sliding sleeve. (→ Page 46)
7.
Alternatives 2:
Condition: Wall/roof duct with extension
Install the extensions. (→ Page 46)
Install the elbows (→ Page 49).
Install the sliding sleeve. (→ Page 46)
Connect all of the pipe joints with air pipe clamps.
(→ Page 54)
Air/flue pipe installation manual 0020308120_02