5.4.1
Scope of delivery
65
5
4
3
1
Wall collar, 100 dia-
meter (2 pcs)
2
Horizontal telescopic
wall duct
5.4.2
Installing the wall duct
1.
Drill a hole.
–
Diameter: 125 mm
Note
If the wall duct can be accessed from the
exterior of the building, you can drill the hole
with a diameter of 110 mm and install the
wall duct with the wall collar from outside.
1
2
2.
Determine the clearance to the external wall.
(→ Page 14)
3.
Set the telescopic wall duct to the correct length.
–
Note that the TOP symbol must point upwards on
both ends.
Danger!
Risk of poisoning due to escaping flue
gas.
Flue gas can escape if a flue pipe is dam-
aged.
▶
Only use the self-tapping screw provided.
16
456-698
Ø167
1
2
3
40 mm clamp
4
87° elbow
5
30 mm clamp
1
4.
Secure the air pipes to each other by screwing the
overlapping air pipes together using the supplied self-
tapping screws on the underside (1).
5.
Seal the gap in the telescopic air pipe using the sup-
plied adhesive tape (2).
6.
Slide the air/flue pipe (1) with the flexible external collar
through the wall.
7.
Pull the air/flue pipe back until the external collar lies
fully on the external wall.
8.
Secure the air/flue pipe with mortar and leave the mor-
tar to harden.
9.
Install the wall collar on the inside of the wall.
10.
Connect the wall/roof duct to the product using ex-
tensions, elbows and, if required, a sliding sleeve.
(→ Page 16)
5.4.3
Installing the roof duct
▶
Insert the air/flue pipe (1) without the external collar into
the dormer.
5.5
Connecting the product
1
2
3
7
6
Install the product (7) – see the installation instructions
1.
for the product.
2.
Connect the 87° elbow (1) to the connector for the
air/flue pipe (6).
3.
Fit the sliding sleeve (3) with the sleeve as far as it will
go onto the wall/roof duct (4) or the extension (5).
4.
If required, install the extensions .
5.
Connect the sliding sleeve to the 87° elbow.
6.
Install the air pipe clamp (2) for the sliding sleeve.
Alternatives 1:
7.
Condition: Wall/roof duct without extension
▶
Install the sliding sleeve. (→ Page 46)
7.
Alternatives 2:
Condition: Wall/roof duct with extension
▶
Install the extensions. (→ Page 46)
▶
Install the elbows (→ Page 49).
▶
Install the sliding sleeve. (→ Page 46)
▶
Connect all of the pipe joints with air pipe clamps.
(→ Page 54)
Air/flue pipe installation manual 0020308120_02