Download Print this page

T&D RTR-574-S Manual

Illuminance uv recorder wl

Advertisement

Quick Links

RTR-574 / RTR-574-S
Introductory Manual
Thank you for purchasing our product.
Carefully read this instruction manual before using this Unit.
RTR-574 Package Contents
Illuminance UV
Illuminance UV
Temperature
AA Alkaline
USB
Recorder WL
Sensor
- Humidity
Battery
Communication
RTR-574
(ISA-3151)
Sensor
Cable (US-15C)
(THA-3151)
RTR-574-S Package Contents
Illuminance UV
Illuminance UV
Temperature
AA Alkaline
USB
Recorder WL
Sensor
- Humidity
Battery
Communication
RTR-574
(ISA-3151)
Sensor
Cable (US-15C)
(SHA-3151)
© Copyright T&D Corporation. All rights reserved.
2017.07
16504670035 (6th Edition)
This is printed using recycled paper.
Illuminance UV Recorder WL RTR-574 is a Data Logger, with built-in wireless communication capability, designed to measure and record
Illuminance, UV Intensity, Temperature and Humidity at a set interval.
Recorded data can be downloaded from an RTR-574 Data Logger (Remote Unit) via wireless communication with a Base Unit; that data can then be viewed in a graph and/or
saved to PC for analysis or sharing over a network.
As a Remote Unit, RTR-574 requires a Base Unit to carry out wireless communication. (Compatible Base Units: RTR-500, RTR-500NW, RTR-500AW,
RTR-500DC, RTR-500MBS-A)
The RTR-574 can be operated with "RTR-500 for Windows" version 1.10 or later.
When you use "RTR-500 for Windows", please check the software version by selecting "Version Info" in the [Help] Menu. The latest version of the
software can be downloaded from our T&D Web Site.
Before using an
RTR-574
, it is first necessary to install the USB Device Driver from the software that comes with the Base Unit.
Appearance Diagram and Part Names
60
Antenna
Sensor Jack
18
POWER Button
Operation Buttons
(DISPLAY, INTERVAL,
REC/STOP)
55
USB Communication
Cable Jack
Battery Cover
78
[Unit : mm]
From hereafter in this manual, Illuminance UV Recorder WL RTR-574
will be referred to as the "Unit".
Introductory
Manual
(including
Warranty)
Introductory
Manual
(including
Warranty)
Reading the LCD Display
REC Mark
The recording status is shown here.
ON: Recording in progress.
BLINKING: Waiting for programmed start.
OFF: Recording has been stopped.
DATA
The number of recorded readings is shown in a scale here. After every
2,000 readings the scale is marked from left to right. Storage capacity is
8,000 readings.
COM Mark
The communication status is shown here.
ON: The Unit is connected to a PC with the USB cable.
BLINKING: The Unit is in Wireless/USB/Serial communication.
Recording Mode
ENDLESS:
Upon reaching storage capacity of 8,000 readings, the oldest data is
overwritten and recording continues.
ONETIME:
Upon reaching storage capacity of 8,000 readings, recording will
automatically stop.
Battery Life
When it is time for the battery to be replaced, this mark will appear.
Warning Mark
Not ON: Ample battery power.
ON: Time to change the battery.
Current Readings /
Normally, the current readings are shown here. Depending on the Unit's
Messages Area
status, operational messages may also be displayed.
Unit of
Humidity: % , Temperature: ˚C / ˚F, Illuminance: lx, klx
Measurement
Cumulative Illuminance: lxh, klxh, Mlxh
2
UV Intensity : mW/cm
,
Cumulative Amount of UV Light: mW/cm
Notices about this Manual
In order to properly use this product, please carefully read this manual before using. T&D Corporation accepts no responsibility for any malfunction of and / or trouble with this product or with your
computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty.
- All rights of this Manual belong to T&D Corporation. It is prohibited to use, duplicate and / or arrange a part or whole of this Manual without the permission of T&D Corporation.
- "TANDD", "T&D" and the logo of T&D Corporation are all registered property of T&D Corporation.
- Specifications, design and other contents outlined in this manual are subject to change without notice.
- We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit. Please be fully aware of this before using our product.
- On screen messages in this manual may vary slightly from the actual messages.
- Please notify the shop where you purchased this product or T&D Corporation of any mistakes, errors or unclear explanations in this manual.
- T&D Corporation accepts no responsibility for any damage or loss of income caused by the use of our product.
- This product has been designed for private or industrial use only. It is not for use in situations where strict safety precautions are necessary such as in connection with medical equipment, whether directly or indirectly.
- This Manual cannot be reissued, so please keep it in a safe place.
- Please carefully read this Manual and Warranty.
Safety Precautions and Instructions
To prevent any loss or damage to our customers, other people and/or property, and to ensure the
proper use of our products we ask that before using our product you carefully read, understand and
follow the safety rules and precautions for our products as outlined below.
Explanation of Warning Symbols
These entries are actions that
absolutely under no circumstance
should be taken. The taking of
DANGER
such an action may cause serious
personal physical damage or
death.
These entries are actions that if
CAUTION
taken may lead to physical injury
or damage to persons or things.
Do not take apart, repair or modify the Unit.
Touching them may result in malfunction or unexpected accidents.
If water or a foreign object enters into the Unit, immediately turn OFF the power, remove
batteries, and stop using.
Continued use may cause fire or electrocution.
Do not use this Unit in wet or humid places, such as a bathroom.
It may cause a fire or other trouble including malfunction.
If water or a foreign object enters the case, immediately cease using it.
Store the Unit and accessories out of the reach of children.
Touching them may result in unexpected accidents.
If any smoke or strange smells are emitted from the Unit, immediately turn OFF the power,
remove batteries, and stop using.
Continued use may cause fire or electrocution.
Do not drop the Unit, or expose the Unit to a strong impact.
If that happens to the Unit, immediately turn OFF the power, remove batteries, and stop using. Continued use
may cause fire or electrocution.
When installing and using this product, make sure to follow all warnings and directions from
your computer manufacturer.
This Unit is not waterproof.
If the Unit gets dirty, wipe it with a clean cloth.
Harmful gases or chemicals may cause corrosion and/or other danger to the Unit. Also, by
coming in contact with hazardous substances, harm may occur to the people handling the
Unit. Therefore, do not use or store the Unit in any environment that is exposed to
chemicals and harmful gases.
Battery life varies depending upon the type of battery, the battery performance, the
measuring environment, and the frequency of communication.
Battery terminals may provide insufficient contact due to age or vibration.
This may lead to data loss.
Use the Unit in an environment within the operational range.
Condensation may occur when a Unit is moved from one environment to another where
there is a great difference in temperature.
To prevent damage to the Unit from static electricity, remove static electricity from your
body by touching metal around you (door knob, window frame) before touching the Unit.
Static electricity may cause not only damage to the Unit, but may cause breaks in or a loss of data.
If the Unit is not to be used for a long period of time, for safety reasons please remove the
battery.
If left in the Unit, it may leak and lead to malfunctioning.Please use a new battery when you use the Unit
again.
Do not store or leave the Unit in any place exposed to high temperature and high humidity.
If the Unit is not to be used for a long period of time, store it in a place with a normal temperature and without
condensation with other items included.
Do not disconnect the communication cable during USB communication.
This may harmfully effect the Unit or your PC.
We shall not guarantee the operation of our device if you have connected it to your
computer using a USB hub or a USB extension cable.
Please do not insert your fingers or any foreign objects into the sensor or USB connection
jacks.
Do not use or store the Unit in any of the following places. Doing so may cause
electrocution, fire and/or other adverse effects to the device and/or your computer.
-Areas exposed to direct sunlight
This will cause the inside of the Unit to become overheated and may cause fire, deformation, and/or
other damage including malfunction.
-Areas prone to strong magnetic fields
This may cause damage including malfunction.
- Areas exposed to water leakage
This may cause electrocution or other damage including malfunction.
- Areas exposed to excessive vibration
This may cause injury, malfunction, damage or loss of proper electrical contact.
- Areas near fire or exposed to excessive heat
This may cause damage including malfunction and deformation.
-Areas prone to dust and dirt
This may cause damage including malfunction.
2
2
h, W/cm
h
* Please carefully observe the following safety measures when using our product.
Cautions about using the Illuminance UV Sensors
Do not connect the ISA-3151 sensor to any data logger other than those specified by T&D
Corporation.
Explanation of Picture Symbols
Use the Unit in an environment within the operational range.
Denotes an important
warning or caution.
When measuring UV light or other light which may cause damage or injury to your eyes or
skin make sure to use protection such as safety glasses or some type of light-proof shield.
Do not expose the sensor to a strong impact.
Denotes a forbidden action.
Cracks or scratches in the Illuminance sensor and / or in the UV sensor will adversely affect the measurement
accuracy. Also, a broken sensor may result in injury.
This sensor is not waterproof. By all means do not allow it to get wet.
Denotes an action that
must be taken.
Do not expose to condensation, dampness, corrosive gases or organic solvents. Also, do
not use in areas near fire or exposed to excessive heat.
DANGER
When the Illuminance UV sensor is not being used, please store at room temperature to
prevent condensation.
If the sensor surface gets dirty, wipe it with a soft cloth.
If the sensor surface accumulates impurities (dirt), it will cause a decrease in the sensor's accuracy and
sensitivity.
If you wish to extend the length of the sensor cable, please purchase and use our optional
sensor extension cable (TR-1C30 / TR-5C10).
Do not cut or process the sensor cables.
Using the "Adjustment Function" in the software supplied with the Base Unit, it is possible to
make desired adjustment settings to a sensor; these settings are saved directly into the
sensor itself.Therefore, when a sensor is replaced, it is necessary to re-make any desired
adjustment settings to be saved into the newly connected sensor.
Cautions about using the Temperature-Humidity Sensors
Do not connect the THA-3001/3151 sensor to any data logger other than those specified by
T&D Corporation.
Use the Unit in an environment within the operational range.
When using the THA-3001/3151 sensor in an environment where the humidity is less than
30%RH, the measurements may sometimes fluctuate. This is not abnormal.
If extremely severe temperature changes occur, the humidity measurements may appear
CAUTION
abnormal.
Once the sensor's temperature becomes stable, the measurements will return to normal.
This sensor is not waterproof.
Only use in an environment where there is no condensation or possibility of becoming wet. Do not use in
water or near areas where high-pressure water is flowing.
Do not expose to condensation, dampness, corrosive gases, or organic solvents.
When the sensor is not to be used for a long period of time, please store it at normal
temperature and humidity.
During use, the surface of the temperature - humidity sensor will accumulate impurities (dirt) causing a
ecrease in the sensor's accuracy and sensitivity. If the sensor is being used in an environment where smoke
and dust are in abundance, periodic calibration may be required.
Do not use this sensor on a human body.
If you wish to extend the length of the sensor cable, please purchase and use our optional
sensor extension cable (TR-1C30 / TR-5C10).
Do not cut or process the sensor cables.
Using the "Adjustment Function" in the software supplied with the Base Unit, it is possible
to make desired adjustment settings to a sensor; these settings are saved directly into the
sensor itself.Therefore, when a sensor is replaced, it is necessary to re-make any desired
adjustment settings to be saved into the newly connected sensor.
FCC Statement
This device complies with Part 15 of the Federal Communications Commission (FCC) rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Caution:
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Note about Antenna Usage:
This device has been designed to operate with the supplied antenna only. Use of any other antenna is strictly prohibited.
IC Statement:
This device complies with RSS-210 of the Industry Canada (IC). Operation is subject to the following two conditions: (1)
This device may not cause harmful interference; and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Ce dispositif est conforme à la norme RSS 210 d'Industrie Canada.
L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes : (1) il ne doit pas produire de brouillage et
(2) l'utilisateur du dispositif doit être prêt à accepter tout brouillage radioélectrique reçu, même si ce brouillage est
susceptible de compromettre le fonctionnement du dispositif.
Wireless products cannot be used in countries other than where those products have been approved for use, according
to that country's wireless regulations.
T&D Corporation shall in no manner whatsoever take responsibility for the usage of these products, nor be liable in any
manner for legal consequences stemming from the usage of these wireless products in unapproved areas.
Wireless Regulations
Important Notice

Advertisement

loading

Summary of Contents for T&D RTR-574-S

  • Page 1 - Specifications, design and other contents outlined in this manual are subject to change without notice. RTR-574 / RTR-574-S - We are not responsible for any malfunction or trouble caused by the use of our product or by any problem caused by the use of measurement results of our unit. Please be fully aware of this before using our product.
  • Page 2 Please get the Base Unit ready first before the RTR-574 (Remote Unit). If no operations can be performed using buttons on the Unit, it means Product RTR-574 RTR-574-S the buttons have been de-activated via the software supplied with the Install the Battery. Temperature...

This manual is also suitable for:

Rtr-574