Connections To The Instrument - Raymarine ST40 Owner's Handbook Manual

Bidata instrument
Hide thumbs Also See for ST40:
Table of Contents

Advertisement

Chapter 3: Installation

Connections to the instrument

Preparing wires for connection
You can connect your instrument:
• Directly to the speed and depth transducers as a stand-alone master
instrument. When connected in this manner, the instrument must be
connected to a suitable power source using the 1 m (3 ft) power
cable provided.
• As part of a SeaTalk system either as a repeater or, with a transducer
also connected as a system master. To connect to SeaTalk, you will
need an additional SeaTalk Interconnection Kit (Part No. E25028).
When connected in this manner, power can be provided from the
SeaTalk bus (e.g. from the autopilot).
You can also connect the instrument to the speed and depth transducers
and to SeaTalk. When thus connected, the instrument will be the master
speed and depth instrument for the SeaTalk system.
If it is necessary to fit spade connectors to the transducer cable, do so as
shown in the following illustration. Prepare the cable, as at (a), and fit
the spade connectors, as at (b). When fitting each spade connector,
ensure that wire strands do not extend beyond the rear of the spade
connector insulation.
50 mm
(a)
4 mm
3 mm
(b)
21
10 mm
D4467-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents