GTG25 F120-5/8
Adjusting support handle
WARNING Risk of severe injury
Air under pressure can cause injury.
Always shut off the air supply when not in use or before any adjustments.
►
Drain the hose of air pressure and disconnect the tool from air supply when not in use or before
►
any adjustments.
Always use the correct hose size and air pressure for the tool.
►
Required tools
■
Allen key (stored within the handle)
Instructions
1.
Loosen the support handle using an allen key.
2.
Adjust the support handle in a suitable position.
3.
Tighten the support handle with the screw to the recommended torque.
WARNING Risk of injury
■
Make sure that the wheel guard is put in a suitable position before operating the tool.
Operating the grinder
DANGER Risk of Injury
There is a risk of injury if the tool is used without the wheel guard.
Always use the tool with the recommended wheel guard.
►
Make sure that the wheel guard is positioned correctly and not damaged.
►
EN
© Atlas Copco Industrial Technique AB - 9839 0590 01
Operation
17