Settings Customer Level; Mode Button Functions - IVT R1000 User Manual

Table of Contents

Advertisement

Settings Customer level

No.
Name
6.1
Generated energy
6.2
Consumption electric additional heat
7
Timers (Timers that are running are displayed)
8
External control
8.1
Heat pump 1
8.1.1
External input 1
8.1.1.14
Room temperature
8.1.2
External input 2 (see 8.1.1)
8.2
Heat pump 2 (see 8.1)
8.5
External input circuit 2 (option)
8.5.2
Block heating at tripped underfloor temperature limiter No
8.5.3
Block heating
8.5.6
Room temperature
8.6
External input circuit 3 (option) (see 8.5)
8.7
External input circuit 4 (option) (see 8.5)
12
General
12.1
Room sensor settings
12.1.1
Show outdoor temperature in room sensor
12.2
Set date
12.3
Set time
12.4
Summer/winter time
12.6
Display contrast
12.7
Language
13
Alarms
13.1
Information log
13.2
Delete information log
13.3
Alarm log
13.4
Delete alarm log
13.7
Alarm indication
13.7.1
Alarm buzzer signal
13.7.1.1
Interval
13.7.1.2
Blocking time
13.7.2
Alarm indication control unit
13.7.2.1
Block alarm buzzer
13.7.3
Alarm indication room sensor
13.7.3.2
Block alarm indicator lamp
14
Access level
15
Return to factory settings
Table 3 Menu overview
6
Settings Customer level
6.1

Mode button functions

By pressing
, the following functions can be used directly:
• Room temperature normal / Temperature increase/decrease
• Hot water mode
• Extra hot water duration
• Party
• Holiday
• Disable cooling
The controller language can be changed with the
button.
▶ Press the
button in the initial menu for at least 5
s, then select the required language.
8
F value
Min.
No (0,0 °C)
10,0 °C
No
No (0,0 °C)
10,0 °C
No
Automatic
50%
20%
No
2s
1s
Off
No
No
Room temperature normal / Temperature increase/decrease
Here, temperature changes for Circuit 1 can be made. If this circuit is
equipped with a room temperature sensor, the display shows Room
temperature normal, otherwise Temperature increase/decrease is
shown.
▶ For description of setting of Room temperature normal
(Chapter 6.2, 1.1.11.3 Room temperature normal ).
▶ For description of setting of Temperature increase/decrease
(Chapter 6.2, 1.1.11.4 Temperature increase/decrease ).
It always takes some time for a change of a heating
setting, e.g. an increase or decrease in room
temperature, to apply. The same applies in the event of a
quick change of the outdoor temperature. This is why
you should always wait for at least 24 hours before
making a new change.
Hot water mode
▶ For description of Hot water mode
(Chapter 6.3, 2.2 Hot water mode ).
Max.
Alternative
35,0 °C
No / Yes
No / Yes
35,0 °C
No / Yes
yyyy-mm-dd
hh:mm:ss
Manual / Automatic
100%
No / Yes
3600s (60min)
Start time 0:00-23:45/
Stop time 0:00-23:45
No / Yes
No / Yes
R1000 – 6 721 831 636 (2021/03) en

Advertisement

Table of Contents
loading