Sharp PN-80TC3 Operation Manual page 49

Hide thumbs Also See for PN-80TC3:
Table of Contents

Advertisement

Initialization/Functional Restriction Setting (FUNCTION) menu
Function
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
EXTERNAL CONTROLLER INPUT
Others
Function
SCREEN SIZE (PC)
SCREEN SIZE (AV)
VOLUME
MUTE
INFORMATION
MODEL
SERIAL NO
TEMPERATURE SENSOR
TEMPERATURE ACQUISITION
CAUSE OF LAST STANDBY MODE
Touch operation valid/invalid
Command
Direction
Parameter
RSET
W
0-1
ALCK
WR
0-2
ALTG
WR
0-2
LOSD
WR
0-2
OFLD
WR
0-1
TALT
WR
0-2
SALT
WR
0-2
PBTN
WR
0-1
PCIP
WR
0-5
Command
Direction
Parameter
WIDE
WR
0-5
WIDE
WR
0-5
VOLM
WR
0-31
MUTE
WR
0-1
INF1
R
SRNO
R
DSTA
R
ERRT
R
STCA
W
0
R
TPEN
WR
0-1
Controlling the Monitor with a PC (RS-232C)
Reply
Control/Response contents
0: ALL RESET 1, 1: ALL RESET 2
0-2 0: OFF, 1:ON1, 2:ON2
When STANDBY MODE is set to LOW POWER, ON2 cannot be selected (ERR).
0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH
"ERR" when OFF is selected for ADJUSTMENT LOCK.
0-2 0: ON1, 1: OFF, 2: ON2
0-1 0: ON, 1: OFF
0-2 0: OFF, 1: OSD & LED, 2: LED
0-2 0: OFF, 1: OSD & LED, 2: LED
0-1 0: MONITOR, 1: EXT. CONTROLLER
0-5 0: D-SUB1, 1: D-SUB2, 2: DisplayPort, 3: HDMI1, 4: HDMI2, 5: HDMI3
"ERR" when MONITOR is selected for POWER BUTTON.
Reply
Control/Response contents
0-5 0: Toggle to change size, 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2
0-5 0: Toggle to change size, 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot
0-31
0-1 0: OFF, 1: ON
Value
Value
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button
2 Main power off by the main power switch
3 Standby mode by RS-232C or LAN
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
0-1 0: Invalid, 1: Valid
"ERR" when TOUCH INPUT SELECT is set to INVALID or the touch panel is not
connected.
*
-
*
-
-
49
E

Advertisement

Table of Contents
loading

Table of Contents