Troubleshooting Check

Troubleshooting Check
✤ Before contacting a service centre, perform the following simple checks.
They might save you the time and expense of an unnecessary call.

Self Diagnosis Display

Display
Blinking
slow
the battery pack is almost discharged.
fast
the battery pack is fully discharged.
slow
the tape has almost reached its end.
TAPE END!
TAPE END!
no
the tape reached its end.
TAPE!
slow
there is no tape in the camcorder.
the tape is protected from recording.
slow
PROTECTION!
D.EMG
slow
the camcorder has some
C.EMG
mechanical fault.
R.EMG
L.EMG
moisture condensation
slow
has formed in the camcorder.
64
All manuals and user guides at all-guides.com
Inform that...
Action
Exchange it with a charged one.
Exchange it with a charged one.
Prepare a new one.
Change to a new one.
Insert a tape.
Check the red tab on the tape
is not pushed over the hole.
1. Eject the tape.
2. Set to OFF.
3. Detach the battery.
4. Reattach the battery.
* Please contact your local
service centre if the problem
continues.
see page 67.