Download Print this page
Dimplex DXLWP400 Installation And Operating Instructions
Dimplex DXLWP400 Installation And Operating Instructions

Dimplex DXLWP400 Installation And Operating Instructions

Low wattage panel heaters

Advertisement

Quick Links

Dimplex Low Wattage Panel Heaters
Models:
DXLWP400, DXLWP400TI
DXLWP800, DXLWP800TI N,
ARLWP800TI
Dimensions
(millimetres)
Models
Specification
DXLWP400
400W Neon Heat Switch
DXLWP400TI
400W Neon Heat Switch / 24 Hour Timer
DXLWP800
800W Neon Heat Switch
DXLWP800TI N
800W Neon Heat Switch / 24 Hour Timer
ARLWP800TI
800W 2 Neon Heat Switches / 24 Hour Timer
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
IMPORTANT SAFETY ADVICE
WARNING –THIS APPLIANCE MUST NOT BE USED IN A BATHROOM
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY
BELOW A FIXED SOCKET OUTLET.
DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS
ARE FITTED CORRECTLY.
FOLLOW these instructions carefully.
The heater carries a warning 'DO NOT COVER' to alert the
user to the risk of fire that exists if the heater is accidentally
covered.
Models DXLWP400TI, DXLWP800TIN and ARLWP800TI can be
set to switch on automatically. Remember to observe all
safety warnings at all times.
If young children, the aged or infirm are likely to be left in the
vicinity of the heater, we advise that adequate precautions
should be taken. We recommend a guard be fitted to ensure
contact with the heater is avoided and objects cannot be
inserted into the product.
If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
For further information, please contact our guard supplier
direct on Tel. No. 01603 667957, or in case of difficulty or for
further advice contact the Customer Helpline.
Electrical Connection
WARNING THIS APPLIANCE MUST BE EARTHED
If the socket outlets in your home are not of the 13 amp BS1363 type
they will not accept the plug connected to this heater, therefore cut off
the plug. When cut off this plug can constitute a shock hazard if inserted
into a socket outlet. It must therefore be disposed of safely.
Before wiring the appropriate plug please note that the wires in this
mains lead are coloured in accordance with the following code.
GREEN/YELLOW - EARTH
BLUE - NEUTRAL
BROWN - LIVE
Connect the Green/Yellow wire to the terminal marked E or the earth symbol
or coloured Green or Green/Yellow.
Connect the Brown wire to the terminal marked L or coloured Red.
Connect the Blue wire to the terminal marked N or coloured Black.
DO NOT connect the Brown (Live) or the Blue (Neutral) wires to the
Earth terminal of your 13 amp plug. If the terminals of the plug are
unmarked or you are in any doubt, consult a qualified electrician.
CAUTION: If you use this heater in conjunction with a thermal control,
programme controller, timer or any other device which switches the
heater on automatically observe all safety warnings at all times.
Installation and Operating Instructions
POSITIONING THE HEATER
Select the position for the heater ensuring there is clearance
from any furniture and fittings of at least 150mm above the
heater, 50mm below (wall mounted) and 25mm each side.
Curtains must not be closer than 150mm from the top of the
heater.
Free Standing Operation (Fig. 1)
NEVER USE THE HEATER FREE STANDING WITHOUT THE FEET
FITTED.
1. Lay the heater on its front.
2. Remove the two socket head screws from the base of the
heater using the hexagon key supplied.
3. Place feet over base of heater, align holes and engage hook
on foot into the recess on the back of the heater.
4. Replace the screws but do not overtighten.
Fig. 1
Rear View
INULUKWPGN / 0 Issue 3
600 mm - 400W
800 mm - 800W
500 mm
(See Fig. 1)
.

Advertisement

loading

Summary of Contents for Dimplex DXLWP400

  • Page 1 Installation and Operating Instructions Dimplex Low Wattage Panel Heaters INULUKWPGN / 0 Issue 3 Models: DXLWP400, DXLWP400TI DXLWP800, DXLWP800TI N, ARLWP800TI Dimensions 600 mm - 400W 800 mm - 800W (millimetres) Models Specification DXLWP400 400W Neon Heat Switch DXLWP400TI 400W Neon Heat Switch / 24 Hour Timer...
  • Page 2 Before using the heater ensure that all warnings and instructions have been read carefully. OPERATION - SINGLE RATED MODELS Digital Timer Operation Models DXLWP400, DXLWP400TI, DXLWP800, DXLWP800TI N Turn the heater on using the switch on the right side of the heater IMPORTANT Remember to observe all safety warnings when - the switch will be illuminated.
  • Page 3 Now set the time by pressing the H (Hour) button and then Fig. 3 M (Minute) button until the desired time setting is displayed. Press the P (Program) button again to finish the first ON setting and enter into the first OFF setting. By repeating steps ‘2’...
  • Page 4 The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336 Glen Dimplex Millbrook House UK customer helpline (8.00AM - 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)

This manual is also suitable for:

Dxlwp400tiDxlwp800Dxlwp800ti nArlwp800ti