Measurements And Adjustments - Panasonic NN-T983SF Service Manual

Hide thumbs Also See for NN-T983SF:
Table of Contents

Advertisement

3 MEASUREMENTS AND ADJUSTMENTS

3.1.
Adjustment of Primary latch
switch, Secondary latch
switch and Short switch.
1. When mounting Primary latch switch,Secondary latch
switch and short switch to door hook assembly, mount the
Primary latch switch, the Secondary latch switch and the
short switch to the door hook assembly as shown in table.
NOTE:
No specific adjustment
Primary latch switch, Secondary latch switch and
short switch to the door hook is necessary.
2. When mounting the door hook assembly to the oven
assembly, adjust the door hook assembly by moving it in
the direction of arrow in the illustration so that the oven door
will not have any play in it. Check for play in the door by
pulling the door assembly. Make sure that the latch keys
move smoothly after adjustment is completed. Completely
tighten the screws holding the door hook assembly to the
oven assembly.
3. Reconnect the short switch and check the continuity of the
monitor circuit and all latch switches again by following the
components test procedures.
NN-T993SF NN-T983SF / NN-S963BF / NN-S963WF / NN-S953BF / NN-S953WF / NN-S943BF / NN-S943WF / NN-S933BF / NN-S933WF
during
installation of
7
3.2.
Measurement of microwave
output
The output power of the magnetron can be determined by
performing IEC standard test procedures. However,due to the
complexity of IEC test procedures, it is recommended to test
the magnetron using the simple method outlined below.
Necessary Equipment:
*1 liter beaker *Glass thermometer
*Wrist watch or stopwatch
NOTE:
Check the line voltage under load.Low voltage will
lower the magnetron output. Take the temperature
readings and heating time as accurately as possible.
1. Fill the beaker with exactly one liter of tap water.Stir the
water using the thermometer and record the beaker´s
temperature. (recorded as T1).
2. Place the beaker on the center of glass cook plate.
Set the oven for High power and heat it for exactly one
minute.
3. Stir the water again and read the temperature of the beaker.
(recorded as T2).
4. The normal temperature rise at High power position for
each model is as shown in table.
TABLE (1L-1min.test)
RATED OUTPUT
1200W(IEC705-88)
1300W(IEC705-88)
1400W(IEC705-88)
TEMPERATURE RISE
Min. 18.5°F(10.3°C)
Min. 19.8°F(11.1°C)
Min. 21.6°F(12.0°C)

Hide quick links: