Vitoflex 300-RF Service & Maintenance

Grate Drive Mechanics Jams

Grate drive mechanics are no longer running causing cinders to accumulate on the grate.
Grate drive
mechanics jammed
Check electrical
triggering system
Check shear-off pin
Clean the connecting
rod and bronze bearing
Check grate
Check grate factory settings

Set the system to "Cleaning", this
causes the grate drive motor to run
continuously.

Check that the shear-off pin on the
connecting rod is OK.

Check that a spare shear-off pin is
present.

Cleaning of the connecting rod and
of the bronze bearing by means of
grease removers.

Check grate for foreign material.

Are all grate components properly inserted?

Lateral play - sliding grate for the concrete;
/
/
3
"
1
" (5
1 mm) (applies up to RF 300)
16
32
/
/
"
" (8
2 mm) (applies up to RF 400/540)
5
1
16
16

Crank axle distance;
RF 100/150 1
"(35 mm)
e
/
RF 220/300 2
" (55 mm)
5
32
/
RF 400/540 3
5
" (80 mm)
32

Setting, stop position, sliding grate "back" crank drive right in
the back - movable grate components, front approx.
(2-4 mm) play (adjustment via threaded rod)

Setting, movable grate components, "front" crank drive right
in the front - movable grate components, front project approx.
/
" (8 mm) beyond the fixed parts and have approx.
5
16
(2-4) mm play (adjustment via adjusting screw at the bottom
on the grate).
Troubleshooting
/
-
/
1
"
5
"
16
32
/
-
/
"
"
1
5
16
32
21