Table 3-1 Insulation Classes; Table 3-2 Machine Design - Siemens SIMOTICS DC 1GG7 Operating Instructions Manual

Table of Contents

Advertisement

Description
Insulation system
The high-quality DURIGNIT® 2000 insulation system means that the motors are suitable for
use in both tropical humidity and industrial environments. You will find the insulation classes
in the following table.
Table 3-1
Series
1GG5
1GH5
1HS5
1HQ5
1GG6, 1GG7
1GH6, 1GH7
1HS6, 1HS7
1HQ6, 1HQ7
Degree of protection
The machine has degree of protection IP23.
Ambient conditions
Unless otherwise specified, the rated powers apply for continuous operation at a coolant
temperature of ≤ 40 °C and an installation altitude of up to 1000 m above sea level. Please
note any data to the contrary on the rating plate. Operating conditions must comply with the
specifications on the rating plate.
Machine design
You will find regulations and standards for rating and testing this motor on the rating plate. The
machine design basically complies with the following standards. Please refer to the EC or EU
Declaration of Conformity for the versions of the harmonized standards referenced.
Table 3-2
Characteristic
Ratings and operating performance
Degree of protection
Cooling
Construction type
Terminal markings and direction of rotation
Noise emission
Vibration severity grades
Vibration limits
20
Insulation classes
Machine design
Insulation class
155 (F)
180 (H)
Standard
IEC/EN 60034‑1
IEC/EN 60034‑5
IEC/EN 60034‑6
IEC/EN 60034‑7
IEC/EN 60034‑8
IEC/EN 60034‑9
IEC/EN 60034‑14
DIN ISO 10816-3