Advertisement

Quick Links

NOTES:
For optimum performance of this product, the recommended system pressure is between
20 and 80 PSI static. This product will operate up to a maximum of 125 PSI static per
ANSI and CSA requirements. However, it is not recommended the pressure go above
80 PSI. Thermal expansion or leaking pressure reducing valves may require the use of
expansion tanks or relief valves to ensure your system never exceeds its maximum
intended pressure setting.
Control Box #0
Designed for routine 180°F (82°C) disinfection cycles up to 10 minutes.
• Use 3-conductor 18AWG wire between transformer and hardwire converter / driver
board earth ground.
• Use Delta Commercial approved transformers and mount the transformer a minimum
of 6" (152 mm) away from the Delta driver board enclosure.
• Refer to Proximity Application Notes on SpecSelect for installation best practices,
proper grounding and wiring diagrams.
061203A
Vandal Resistant Laminar Outlet
with Wrench
0.5 GPM (1.9 L/min)
060638A - Optional
Vandal Resistant Laminar Outlet
with Antimicrobial by Agion
®
1.5 GPM (5.7 L/min)
060640A - Optional
Vandal Resistant Flow Control
Aerator and Wrench
1.5 GPM (5.7 L/min)
060642A - Optional
Flow Control Aerator
1.5 GPM (5.7 L/min)
RP31704 - Optional
Vandal Resistant Spray Outlet
with Wrench
0.5 GPM (1.9 L/min)
060566A - Optional
Vandal Resistant Spray Outlet
with Wrench
1.0 GPM (3.8 L/min)
060905A
Cover Gasket
060906A
Surface
Mount Housing
061252A
Dual
Driver Board
063258A
Surface Box assembly (less driver board)
w/3/4" solenoid and adaptors for 3/8" compression
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
59
Write purchase model number here for future reference
INSTALLATION AND SET-UP INSTRUCTIONS
Model Number
59x-PLGHDF
59x-PLGHDFHW
RP30522
Gasket
060765A
Wrench
062032A
Braided Polymer Hose
063257A
3/4" Solenoid Valve
w/adaptors for 3/8"
Compression
060908A
Solenoid Holder
062032A
Braided Polymer Hose
w w w . s p e c s e l e c t . c o m
Page 1
-PLGHDF
__
Description
Battery Operated Surface Mount Box #0
Hard Wire Operated Surface Mount Box #0
063129A
HDF Spout
Assembly
for Proximity
061175A
Spacer package
for HDF Proximity
060683A
24VAC to 6VDC Converter
RP6087
061259A
Nut &
Ground Wire Kit
Washer
(for hardwire models)
061047A
24VAC to 6VDC Converter with
061206A
Battery Backup
Proximity
061256A
Sensor
36" Sensor Module Extension Cable
Module
__ __
Page #
2
4
061159A
4" Deck Plate
& Holddown Pkg
061160A
8" Deck Plate
& Holddown Pkg
063254A
Nut & Washers
OPTION LIST
060681A
Battery Holder
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
DECK PLATES
061159A
4" Deck Plate & Hold-Down Pkg
061160A
8" Deck Plate & Hold-Down Pkg
212187 Rev. B

Advertisement

Table of Contents
loading

Summary of Contents for Delta 59 PLGHDF Series

  • Page 1 Designed for routine 180°F (82°C) disinfection cycles up to 10 minutes. • Use 3-conductor 18AWG wire between transformer and hardwire converter / driver board earth ground. • Use Delta Commercial approved transformers and mount the transformer a minimum 061159A of 6” (152 mm) away from the Delta driver board enclosure.
  • Page 2: Installation And Set Up Instructions

    Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 59x-PLGHDF Battery Operated Surface Mount Box #0 INSTALLATION AND SET UP INSTRUCTIONS Fig. 1 STEP 1. FAUCET INSTALLATION Spout Mount faucet to sink using the provided components in the following order - grey bottom spacer, washer, lock nut (Fig.
  • Page 3 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 59x-PLGHDF Battery Operated Surface Mount Box #0 INSTALLATION AND SET UP INSTRUCTIONS STEP 8. TEST FOR OPERATION Test for operation. If OK, then close lid - Use caution not to damage wires or components on electronic driver board.
  • Page 4 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 59x-PLGHDFHW Hard Wire Operated Surface Mount Box #0 INSTALLATION AND SET UP INSTRUCTIONS Fig. 7 STEP 1. FAUCET INSTALLATION Spout Mount faucet to sink using the provided components in the following order - grey bottom spacer, washer, lock nut (Fig.
  • Page 5 Installation should be in accordance with local plumbing and electrical codes. FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 59x-PLGHDFHW Hard Wire Operated Surface Mount Box #0 INSTALLATION AND SET UP INSTRUCTIONS CONDUCTIVE SINKS NON-CONDUCTIVE SINKS Fig. 12 Fig. 13 Metal Sink Mounting Hardware or Bracket Sink Ground...
  • Page 6: Making Adjustments

    ● bAd - Replace Batteries (buzzer will annunciate and LED will blink if activated - if these features are turned on) If you have any questions about the installation of this product or need help troubleshooting this product, please call Delta Commercial Technical Services at 1-800-387-8277 (Canada) or 1-877-509-2680 (U.S.A.).
  • Page 7: Care Instructions

    CARE INSTRUCTIONS This Delta Commercial faucet is designed and engineered in accordance with the highest quality and performance standards. With proper care, it will give years of trouble free service. Care should be given to the cleaning of this product. Although the chrome finish is extremely durable, it can be DAMAGED by ACIDIC CLEANERS (i.e.
  • Page 8 TROUBLESHOOTING GUIDE Check to ensure faucet was installed Note: See attached M&I, pages 1 to 6. according to the M&I sheet. Test for operation. If unit does not Verify spacers are in place; black spacer on top and grey spacer on the operate: bottom of the sink or counter.
  • Page 9 ® All parts of Delta® HDF® and TECK® faucets are warranted to the original commercial purchaser to be free from defects in material, nish and workmanship for a period of ve (5) years unless otherwise speci cally stated in the catalogue and price book. This warranty is made to the original commercial purchaser and shall be e ective from date of purchase as shown on the purchaser’s receipt.

This manual is also suitable for:

59 plghdfhw series

Table of Contents