Diaphragm Repair

Tools Required
Torque wrench
13 mm socket wrench
15 mm socket wrench (aluminum models) or
1 in. socket wrench (stainless steel models)
19 mm open-end wrench
O-ring pick
Lithium-base grease
Disassembly
NOTE: A Fluid Section Repair Kit is available. Refer to
page 23 to order the correct kit for your pump. Parts
included in the kit are marked with an asterisk, for
example (401*). Use all the parts in the kit for the best
results.
____________________________________________________________
F
. 11
IG
18
308441ZAH
3
Service
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 11.
1. Relieve the pressure.
2. Remove the manifolds and disassemble the ball
check valves as explained on page 17.
3. Using a 13 mm socket wrench, remove the screws
(106 and 112) holding the fluid covers (101) to the air
covers (23). Pull the fluid covers (101) off the pump.
See F
IG
1
2
3
B
23
WARNING
. 11.
Apply medium-strength (blue) thread locker to the
threads. Torque to 190-220 in-lb (22-25 Nm). See
Torque Instructions, page 29.
Arrow (A) must point toward air valve (B).
Muffler not included on Model No. 253485.
101
2
A
106
112
1
1
03273C