CHAPTER 1: SAFETY INSTRUCTIONS
I I M M P P O O R R T T A A N N T T
Preventative maintenance is crucial to maintaining the function and safety of this equipment. Your
facility must establish written guidelines for preventative maintenance and keep written or online
records of the maintenance performed on these products. As a minimum, the items presented in
the SAFETY section of this document and the items that follow here, should be included in your
maintenance program.
1. Cables (If equipped): inspect end fittings daily for wear. Inspect the entire length of the
cable weekly. Replace cables at the first sign of wear and on an annual basis. If the cable
tension has been adjusted, be certain that the cable nut is tight.
2. Nuts, Bolts, and Fasteners: check tightness weekly. If any hardware has become loose,
retighten and/or use Loctite
using the machine.
3. Safety Catches: inspect catches, stop rods and their associated fasteners weekly. Tighten
any loose hardware and replace any components at first signs of wear.
4. Frames: sweat, disinfecting sprays and spills can lead to corrosion which may lead to
premature failure of components. Wipe all machines down with a damp cloth and dry
completely each day. This includes painted parts, chrome parts and upholstered pads.
5. Painted and chrome plated parts: use Simple Green with a dilusion of 32:1 or similar
cleaner for light dirt and grime. Use Turtle Wax Polishing Compound or a good car polish to
remove heavier dirt and grease as well as for polishing. DO NOT use solvents, lacquer
thinner, acetone or finger nail polish remover. For scuffs and marks that are not removed
by the above methods use a soft scrub cleanser. Make sure all parts are dry upon
completion.
6. Weight stack enclosures (shrouds)(If Equipped): wipe down with a damp cloth as needed.
7. Exercise instruction labels: clean with soap and water as needed.
8. Guide rods (If equipped): wipe all dirt and dust from the guide rods before applying a light
application of Tri-Flow
then wipe the guide rods with the rag. DO NOT use oil lubricants such as WD-40. Caution: Tri-
TM
Flow
will stain carpet and clothing.
9. Bronze bushings: check monthly for signs of wear and replace as needed.
10.
Linear Bearing Shafts: wipe any accumulation of dust or other contaminants from the
shafts on a weekly basis. Apply a thin layer of a Teflon
TRUE recommends Magnalube
11.
When replacing any component, use only TRUE supplied parts.
12.
Be sure all hardware is tight before using the machine.
Retain these instructions for future reference.
If you have any questions, do not hesitate to contact your TRUE dealer or TRUE Fitness Technology
at (800)883-8783 or service@truefitness.com.
True Fitness Technology • O'Fallon, MO • Phone: 800-426-6570/636-272-7100 • Truefitness.com
G
ENERAL
TM
brand Threadlocker 242. Be sure all hardware is tight before
TM
or other teflon spray lubricant. Spray the Tri-Flow
®
brand.
7
C
M
ARE AND
AINTENANCE
®
(PTFE) grease on a weekly basis.
Strength
Atlas 200/201
TM
on a rag and
Page # 8 of 54