You have two options for installation. Pick which one works best for your location. Remove any existing
bracket prior to installation. Only use the provided Hunter ceiling bracket that came in your fan's box.
Do this first!
OFF
Option 1:
Machine Screws
Use machine screws
(provided with outlet box)
and washers when securing
to existing ceiling fan-rated
outlet box. Make sure it is
securely installed and is
acceptable for fan support of
31.8 kg (70 lbs) or less.
For angled ceilings,
point opening
toward peak.
Follow below if you are using the downrod that came pre-assembled in your box. Need to
install a longer or shorter downrod? Check out the guide at the end of this manual.
1
Slide the adapter cover onto
the downrod until it rests
against the hanger ball.
Hunter Pro Tip:
The adapter cover is not used for
low-profile mounting.
Ceiling Bracket
Downrod
Installing the Downrod
2
Remove the pre-installed
setscrew so that the
downrod can be inserted.
Hanging Fan
Wiring
Option 2:
Wood Screws
Use wood screws and
washers (included) when
securing to support structure
with approved electrical
outlet box. Drill 9/64" pilot
holes in support structure
to aid in securing ceiling
bracket with hardware found
in the
Canopy
Blades
Hunter Pro Tip:
The machine screws are the ones
that came with your outlet box.
hardware bag.
bag
Hunter Pro Tip:
3
The ground wire attached to the
downrod is approximately 8 inches.
Pass all wires to one side of horizontal bar
in downrod assembly. Hand tighten the
downrod (at least 4–5 full turns) until it
stops. Trim the wires coming from the fan
so that 8-inches remain coming from the
top of the downrod.