NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
Fueling The Heater:
Paraffin
For optimal performance of this heater, it is
strongly suggested that Paraffin be used.
Paraffin has been refined to virtually eliminate
contaminants, such as sulfur, which can cause
a rotten egg odor during the operation of the
heater. Using diesel fuel can cause excess soot
production. Do not use Bio-Diesel or Farm "red"
diesel as this fuel will damage your heater's seals
and filter.
Factory tested for use with paraffin, no. 1 &
no.2 diesel, JP8/Jet A Fuel, no. 1 and no. 2
fuel oil.
NEVER REFUEL THIS HEATER
DANGER
WHILE IT IS HOT OR
OPERATING. FIRE OR EXPLOSION COULD
RESULT.
NEVER FILL THE FUEL TANK
CAUTION
INDOORS. ALWAYS FILL
THE TANK OUTDOORS. BE SURE THAT
THE HEATER IS ON LEVEL GROUND WHEN
FUELING, AND NEVER OVERFILL THE TANK.
DO NOT USE GASOLINE OR
WARNING
CRANKCASE DRAININGS.
- NEVER use fuel such as, benzene, alcohol, white
gas, camp stove fuel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR
EXPLOSION.
- NEVER store Paraffin in the living space. Paraffin
should be stored in a well ventilated area outside
the living area.
- NEVER store Paraffin in direct sunlight or near a
source of heat.
- NEVER use Paraffin that has been stored from one
season to the next. Paraffin deteriorates over time.
OLD Paraffin WILL NOT BURN PROPERLY IN
THIS HEATER.
© 2021 Pinnacle Climate Technologies, Inc.
WHILE CONNECTED TO A POWER SOURCE

Operation

NOTE: Paraffin should only be stored in
a blue container that is clearly marked
"Paraffin." Never store Paraffin in a red
container. Red is associated with gasoline.

Ventilation:

- Risk of indoor air pollution and Carbon
Monoxide Poisoning. Use heater only in well
ventilated areas.
- Refer to Safety Information on pages 1-2 for
information about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated
space of at least 2,800 square centimeters
(3 sq. ft) for each 29 kW (100,000 Btu / Hr.) of
heater output. Provide a larger opening if more
heaters are being used.
CARBON MONOXIDE POISONING
DANGER
MAY LEAD TO DEATH!
This appliance is designed to
WARNING
operate safely at a minimum
ambient temperature of -20° C.
Use caution when servicing in
WARNING
wet areas. Disconnect power
from the power mains and keep all electrical
components from becoming wet. Only a
qualified technician should service the
heater
A qualified technician is
WARNING
required to install, adjust and
where necessary; convert this heater for use
with other fuel types.
Minimum Ventilation Opening Needed
ST-70-SS-E /
ST-70T-SS-E
1950 cm
2
8
ST-125-OFR-E
3484 cm
2

Advertisement