Summary of Contents for American Standard 3052OD.X0X
Page 1
ST5232DC THANK YOU... for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The combination tub version is completely assembled with pump, motor, and system piping. All you need to finish the combination tub installation are your selected fittings and electrical connections.
Page 2
CONGRATULATIONS! You are now the owner of a walk-in bathtub from the most trusted name in plumbing. We thank you for your purchase. Your American Standard walk-in bath is a true ® investment in your health and peace of mind.
OWNER’S MANUAL TABLE OF CONTENTS: UNPACKING THE UNIT ..................Page 4 RESPONSIBILITIES OF THE INSTALLER ............Page 5 TESTING YOUR TUB BEFORE INSTALLATION..........Page 6 INSTALLATION PREPARATION ................Page 7 ELECTRICAL INSTALLATION................Page 8 INSTALLATION PROCEDURES..............Page 9-17 SAFETY INSTRUCTIONS..................Page 18 OPERATING INSTRUCTIONS ..............
3. Immediately inspect the unit for damage even if there is no carton damage. All product damage must be reported within 72 hours of receipt from American Standard . Once the unit is installed, surface damages will ®...
Quick Drain . American Standard® does not accept responsibility for damage arising from use of the Quick Drain Only accessories authorized by manufacturer should be used with this product.
OWNER’S MANUAL TESTING YOUR WALK-IN TUB BEFORE INSTALLATION 1. All American Standard walk-in baths are 100% water tested at the factory and have passed inspection. ® Transportation and mishandling may loosen fittings and cause leaks. It is therefore necessary to test the bathtub while there is access to all sides of the bath.
OWNER’S MANUAL INSTALLATION PREPARATION 1. Check the floor area where the tub is to be installed. a. Clean area of any debris or trash. b. Use a 5 or 6-foot level and determine if the floor is level. If the floor is not level, adjust all leveling feet to perfectly level the tub.
OWNER’S MANUAL ELECTRICAL INSTALLATION All electrical wiring must be installed in accordance with the National Electrical Code and with all local codes. All wiring shall be done by a qualified electrician. Run one, two or three branch circuits (as required) from the main electrical service panel to the pump area of the framing structure to provide power to the unit.
WARNING: Danger: Risk of electrical shock; connect components to separate circuits, EACH protected by a ground fault circuit interrupter (GFCI) WARNING: Installation must provide access for servicing the pump and motor (all American Standard ® walk-in baths come with access panels for the pump, motor and faucet).
Page 10
OWNER’S MANUAL INSTALLATION PROCEDURES (continued) WARNING: Never allow the weight of the tub to be supported by wood support stringers and do not use integral tile flange (if equipped) to screw or nail in place, as this will result in product failure and will void the warranty.
Page 11
OWNER’S MANUAL ALCOVE INSTALLATION 52" (1321mm) 13" (330mm) WALL WALL STUD TILE 16-1/2" GALVANIZED (419mm) NAIL SILICONE TILE FLANGE 30" (762mm) NON-INTEGRAL FLANGE 40" (1016mm) ROUGH FLOOR Tubs installed in an alcove installation require a raised flange to prevent water from seeping past the tub and into the wall. Tubs without a raised flange shall be installed with a tile flange kit such as model: 9FLNG or a similar type.
Page 13
OWNER’S MANUAL ACRYLIC EXTENSION KIT INSTALLATION The Acrylic Extension Kit is designed to accommodate all acrylic walk-in tubs to fit within a 60" alcove pocket. The top panel measures 30" x 20" (depth x width) and the front panel 37-1/2" x 20" (height x width). The panels must be trim to fit the unit within the 60”...
Page 14
OWNER’S MANUAL ACRYLIC EXTENSION KIT INSTALLATION Step 5 & 6 • Remove the tub from the alcove and install the front and then top panel with the self tapping fasteners. Predrill screw holes and Predrill screw holes and attach front panel to apron attach top deck of tub Self tapping screw Self tapping screw...
Page 15
/ overflow kit. After the drain is fully installed, test the unit for proper drainage. If the unit does not drain properly, rectify the condition before proceeding with installation. American Standard is not responsible for the removal or re-installation costs.
Page 16
OWNER’S MANUAL THRESHOLD DRAIN INSTALLATION THRESHOLD DRAIN INFORMATION All gel coat walk-in bathtubs are provided with a threshold door drain. All acrylic walk-in bathtubs feature the “Patented T5 Door System” which does not require the threshold drain. CONNECTION OF THE DOOR DRAIN •...
Page 17
OWNER’S MANUAL INLINE HEATER INSTALLATION WHIRLPOOL IN-LINE HEATER All whirlpool systems are deigned with an In-Line Heater Blank. The threads and union set on the heater blank and heaters are specifically designed for our system. All other heaters and heater blanks will not interchanges with our system.
OWNER’S MANUAL IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. WARNING: Risk of personal injutry. Use this unit for its intended use as described in this manual. DO NOT use attachments not recommended by the manufacturer.
OWNER’S MANUAL SAVE THESE INSTRUCTIONS! OPERATING INSTRUCTIONS 1. Enter your American Standard walk-in bath, close the door, place handle in down position, and fill the bath ® to at least 2 inches above the highest jet before activating the whirlpool pump (if equipped). Do not apply excessive pressure when placing the handle in the close position.
Page 20
OWNER’S MANUAL SAVE THESE INSTRUCTIONS! OPERATING INSTRUCTIONS (continued) 9. If your American Standard walk-in bath is equipped with Chromatherapy lights, the lights have a ® dedicated control button. Pressing the control button off and back on will change the color of light.
OWNER’S MANUAL CLEANING AND MAINTENANCE Pump and pipe circulation systems should be flushed before first use and on a monthly basis when product is under normal use. Below are the recommended procedures for cleaning: • Do not run whirlpool dry. Fill the tub with hot water 2-3 inches above the jets and add 2-3 teaspoons of low foaming detergent such as dishwashing machine detergent.
Requests for returns and/or exchanges must be made within 30 days of receipt of product. The product must be in its original packaging and received at American Standard in saleable condition. All returns will receive a 15% restocking fee plus all freight costs of the original shipment and return shipment to American Standard.
OWNER’S MANUAL TROUBLE SHOOTING GUIDELINES WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED. To reduce the risk of injury, keep all components in a vented enclosure and out of the reach of children. Risk of Electrical Shock – Connect only to a grounding type receptacle protected by a ground fault circuit interrupter (GFCI).
Page 24
OWNER’S MANUAL TROUBLE SHOOTING GUIDELINES (continued) WHIRLPOOL PUMP MOTOR WILL NOT START – CHECK FOR: • Check the air line between the motor and air button for connection and depress to test air signal. • Improper or loose connections, open switches or relays, blown circuit breakers. •...
Page 25
OWNER’S MANUAL TROUBLE SHOOTING GUIDELINES (continued) HEATERS All heaters are equipped with a preset pressure switch which will not allow the heater to turn on if the pump is not running with water flowing through the whirlpool system. The heater includes an exclusive High Limit Switch.