Communication Parameters
Baud rate : 9600 bps ( UART )
A
Data length : 8 bits
A
Parity : None
A
Command Reference List
01. Power
02. Aspect Ratio
03. Screen Mute
04. Volume Mute
05. Volume Control
06. Contrast
07 . Brightness
08. Colour
09. Tint
10. Sharpness
1 1. OSD Select
1 2. Remote control lock mode k
1 3. Treble
1 4. Bass
1 5. Balance
1 6. Colour Temperature
1 7 . Abnormal Status
1 8. ISM Method
19. Energy Saving
20. Auto Configuration
21. Tune Command
22. Channel Add/Skip
23. Key
24.Input select (Main)
* When setting the 17 ~ 24, a menu does not appear on
screen.
* Note: During USB operations such as Dvix or EMF, all
commands except Power (ka) and Key (mc) are not exe-
cuted and treated as NG.
Downloaded From TV-Manual.com Manuals
Stop bit : 1 bit
A
Communication code : ASCII code
A
Use a crossed (reverse) cable.
A
COMMAND
COMMAND
DATA
1
2
(Hexadecimal)
k
a
00 ~ 01
k
c
Refer to p. 1 18
k
d
Refer to p. 1 18
00 ~ 01
k
e
k
f
00 ~ 64
k
g
00 ~ 64
k
h
00 ~ 64
00 ~ 64
k
i
k
j
00 ~ 64
k
k
00 ~ 64
k
l
00 ~ 01
00 ~ 01
m
k
r
00 ~ 64
k
s
00 ~ 64
k
t
00 ~ 64
00 ~ 02
k
u
k
z
j
p
Refer to p. 120
j
q
Refer to p. 120
j
u
01
m
a
Refer to p. 120
m
b
00 ~ 01
m
c
Sende IR-kode
x
b
Refer to p. 121
Transmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1] : First command to control the TV.
* [Command 2] : Second command to control the TV.
* [Set ID]
: You can adjust the set ID to choose
* [DATA]
: To transmit command data.
* [Cr]
: Carriage Return
* [ ]
: ASCII code 'space (0x20)'
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The set transmits ACK (acknowledgement) based on
FF
this format when receiving normal data. At this time, if
the data is data read mode, it indicates present status
data. If the data is data write mode, it returns the
data of the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The set transmits ACK (acknowledgement) based on
this format when receiving abnormal data from
non-viable functions or communication errors.
Data 00: Illegal Code
(j, k, m or x)
desired monitor ID number in option
menu. Adjustment range is 1 ~ 99.
When selecting Set ID '0' , every connect-
ed set is controlled.
Set ID is indicated as decimal (1~99) on
menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
Transmit 'FF' data to read status of com-
mand.
ASCII code '0x0D'
117