10. Electrical characteristics

Model name
Voltage
Power
supply
Frequency
Max operating current *1
Starting current
Circuit breaker current
Power cable
Wiring
spec. *2
Connection
cable *3
*1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
mm
Cross-sectional area
mm
Limited wiring length
AOYG22KBTB
V
Hz
A
A
A
2
2
m
- 43 -
230 ~
50
12.6
8.2
16
1.5
1.5
31
10. Electrical characteristics