ERQ125A7W1B
ERQ200A7W1B
ERQ250A7W1B
C
ONTENTS
About L∞p by Daikin ......................................................................... 1
1. Introduction ................................................................................ 2
1.1. Combination ................................................................................. 2
2. Main components....................................................................... 2
8. Field wiring................................................................................. 7
9. Pipe insulation.......................................................................... 12
12.3. Field setting................................................................................ 15
12.4. Test operation ............................................................................ 17
READ THIS MANUAL ATTENTIVELY BEFORE STARTING
UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN
YOUR FILES FOR FUTURE REFERENCE.
IMPROPER
INSTALLATION
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY
DESIGNED
EQUIPMENT AND
PROFESSIONAL.
DAIKIN EQUIPMENT IS DESIGNED FOR COMFORT
APPLICATIONS. FOR USE IN OTHER APPLICATIONS,
PLEASE CONTACT YOUR LOCAL DAIKIN DEALER.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DEALER FOR ADVICE AND
INFORMATION.
THIS AIR CONDITIONER COMES UNDER THE TERM
"APPLIANCES NOT ACCESSIBLE TO THE GENERAL
PUBLIC".
The English text is the original instruction. Other languages are
translations of the original instructions.
ERQ125~250A7W1B
Inverter condensing unit
4PW51323-1D - 2022.10
OR ATTACHMENT
FOR
USE
WITH
HAVE THEM
INSTALLED
Inverter condensing unit
A
L∞
BOUT
Page
L∞p by Daikin is part of Daikin's wider commitment to reduce our
environmental footprint. With L∞p by Daikin we want to create a
circular economy for refrigerants. One of the actions to achieve this,
is the reuse of reclaimed refrigerant in units produced and sold in
Europe. For more information about the countries that are in scope,
visit: http://www.daikin.eu/loop-by-daikin.
The refrigerant R410A requires strict cautions for keeping
the system clean, dry and tight.
Clean and dry
Foreign materials (including mineral oils such as
SUNISO oil or moisture) should be prevented from
getting mixed into the system.
Tight
R410A does not contain any chlorine, does not
destroy the ozone layer, and does not reduce the
earth's protection against harmful ultraviolet radiation.
R410A can contribute slightly to the greenhouse effect
if it is released. Therefore we should take special
attention to check the tightness of the installation.
Read
these procedures correctly.
Since design pressure is 4.0 MPa or 40 bar, pipes of larger
wall thickness may be required. The wall thickness of
piping must be carefully selected, refer to paragraph
"6.2. Selection of piping material" on page 4
details.
Do NOT connect the system to DIII-net devices:
This could result in malfunction or breakdown of the total system.
OF
THE
BY A
Installation manual
D
P BY
AIKIN
"6. Refrigerant piping" on page 4
carefully and follow
for more
Installation manual
1