Advertisement

INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
RETAIN FOR FUTURE REFERENCE.
WARNING:
4. Attach Housing to Mast Arm Adapter -
Remove the WIREWAY PLUG from the
HOUSING. Move the fixture leads aside so
the THREADED RODS may be accessed
through the fixture HOUSING.
See Figure 4a.
Attach the MAST ARM ADAPTER to the
HOUSING by inserting the threaded studs
into the fixture HOUSING. Feed the fixture
wires through the MAST ARM ADAPTER.
Slide the HOUSING over the threaded
rods and secure it with the PLAIN
WASHERS, LOCK WASHERS, and HEX
NUTS. See Figure 4b.
Torque HEX NUTS as follows:
Medium Icon (ICM) - 450 in-lbs.,
Small Icon (ICS) - 130 in-lbs.
WARNING
Risk of Personal Injury
Fixture may become damaged and/or
unstable if not installed properly
Tighten all fixture components to their
recommended torque values
NOTE: It may be helpful to use a deep
socket when installing the HEX NUTS.
Re-install the WIREWAY PLUG into the
wireway in the HOUSING.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user's purpose, please
contact your nearest representative.
TM
Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
Fig. 4a
Fig. 4b