Other Components continued: 
At this point you can access the primary air control 
damper assembly, thermostatic actuator assembly 
and the damper release lever.  Although these 
shouldn't need to be replaced, they can be easily. 
The primary air control damper assembly can be 
replaced by removing the small spring handle 
from the front of the unit, then sliding the 
assembly out.  Replace by sliding the new 
assembly through the same hole and the rod 
through the front of the stove.  Replace the spring handle.  The thermostatic actuator assembly 
can be replaced by using a 5/16" socket to remove the two screws that hold the assembly. 
Install the new assembly using the same two screws.  The damper release lever can be replaced 
by removing the ½" bolt.  When reinstalling the damper be sure it is installed the same as when 
removed. 
 
Blower:  The wood stove was also designed for use with a convection blower for additional heat 
circulation.  The stove is constructed with side convection channels which allow the room air 
blower to pick up heat from the hottest regions of the stove and transfer it into the home.  The 
mounting screws for the blower are installed into the rear convection channel at the factory; 
mounting the blower only requires a 5/16" open end or socket wrench to remove these screws 
and install the blower.  When routing the power cord, take care to keep away from hot areas of 
the unit and remember that this blower is for use only with the stove.  Please see the diagram 
below for clarification on the room air blower installation.  This unit can use the AC‐16 (which 
comes standard with the unit) or the AC‐30 upgrade blower. Both are installed using the four 
factory installed 5/16" screws. 
The optional heat circulation blower on this stove requires periodic lubrication; this lubrication should be performed 
no less than every three months of normal operation.  To properly lubricate the blower, use an eye dropper or 
similar dispensing device to drip 5‐7 droplets of SAE 20 oil into the oil port on the side of the blower motor 
 
 
 
 
 
 
 
 
 
 
Side Heat Shield (Part AC‐W01SHS): 
Install the side heat shield behind the side flange of the rear panel.  Align 
the two mounting holes and secure with the two screws provided.
OPTIONAL ACCESSORIES  
(4) 5/16" head, self‐tapping 
screws (pre‐installed in unit). 
Warning: Disconnect power 
from fan before installation. 
Page | 25
 