Carrier PHD4 F Series Installation Instructions Manual page 36

14 seer single-packaged heat pump system with r-410a refrigerant, single/three phase 2 5/3-5 nominal tons sizes 24/36-60
Table of Contents

Advertisement

R- -410A QUICK REFERENCE GUIDE
R- -410A refrigerant operates at 50- -70 percent higher pressures than R- -22. Be sure that servicing equipment and replacement
S
components are designed to operate with R- -410A
R- -410A refrigerant cylinders are rose colored.
S
Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400 or DOT BW400.
S
R- -410A systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose when
S
charging into suction line with compressor operating
Manifold sets should be minimum 700 psig high side and 180 psig low side with 550 psig low- -side retard.
S
Use hoses with minimum 700 psig service pressure rating.
S
Leak detectors should be designed to detect HFC refrigerant.
S
R- -410A, as with other HFCs, is only compatible with POE oils.
S
Vacuum pumps will not remove moisture from oil.
S
Do not use liquid- -line filter driers with rated working pressures less than 600 psig.
S
Do not leave R- -410A suction line filter driers in line longer than 72 hours.
S
Do not install a suction- -line filter drier in liquid line.
S
POE oils absorb moisture rapidly. Do not expose oil to atmosphere.
S
POE oils may cause damage to certain plastics and roofing materials.
S
Wrap all filter driers and service valves with wet cloth when brazing.
S
A factory approved liquid- -line filter drier is required on every unit.
S
Do NOT use an R- -22 TXV.
S
Never open system to atmosphere while it is under a vacuum.
S
When system must be opened for service, recover refrigerant, evacuate then break vacuum with dry nitrogen and replace filter
S
driers. Evacuate to 500 microns prior to recharging.
Do not vent R- -410A into the atmosphere.
S
Observe all warnings, cautions, and bold text.
S
All indoor coils must be installed with a hard shutoff R- -410A TXV metering device.
S
36
Specifications are subject to change without notice.
51801200404

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wph4 b series

Table of Contents