LIGHTING THE WATER HEATER
TEST THE WATER HEATER AFTER INSTALLATION
The operation of the water heater must be thoroughly checked by the
installer.
The burner flame must light smoothly and quickly from the pilot flame, and
must go out quietly and completely.
The main burner flame must be stable, although slight lifting at the front
edge of the burner is acceptable when the burner is cold.
The main burner flame should be blue, with a clearly defined inner cone -
luminous yellow or "floating" flames are not acceptable, and must be
corrected by opening the air shutter (refer to
Check the test point pressure and compare with the rating label. The
pressure regulator is not adjustable and if the test point pressure is not
within 5% of the specified value, refer to Rheem Service or their nearest
Accredited Service Agent.
If unable to get the water heater working properly, contact Rheem Service
or their nearest Accredited Service Agent.
When satisfied everything is working properly instruct the user in the correct
method of operation.
AIR SHUTTER
The air shutter is a hinged flap in the burner aeration tube. It may require
adjustment on installation.
For a Propane model, the air shutter should be fully open.
The shutter is held in place by a screw on the side of the burner aeration
tube.
Note: A Natural gas model does not have an
air shutter.
CLOSE DOWN PROCEDURE
1.
Turn the gas control knob to the
"" position (pilot). This setting will leave
the pilot flame alight however the main
burner will not be able to light.
2.
Turn the gas control knob to the "" (off)
position. This setting shuts the gas
control down completely.
"Air Shutter"
36
on page 36).